{"title":"Pump Kits","description":"\u003cp\u003eWater pump kits, each built to solve a specific job. We use our experience specifying pumps to prepare a kit for common problems, matching the pump, hose, fittings and accessories to the task, so you can pick a kit to deal with flooding, site dewatering, pools, hot tubs, gardens or water transfer without working out hose sizes or compatible connections yourself. Many also form part of our FPS Engineered™ selection, specified as complete combinations around the application.\u003c\/p\u003e","products":[{"product_id":"floodmate-flood-protection-kit","title":"FloodMate Kit:  Flood Defence with Water Pump 3in1","description":"\u003cp data-mce-fragment=\"1\"\u003eFloodMate Kits are a complete package of emergency pumping equipment, capable of protecting properties from low-level flooding.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThey include a powerful pump, two packs of Hydrosacks, and discharge hoses. Depending on the chosen kit, the pump can reduce water levels to as low as 3mm or even 1mm.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe lightweight hoses are easy to position and feature quick-connect fittings for rapid deployment during emergencies.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ehe whole kit is packaged in a small, lightweight carry case for easy transportation and storage.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWhat's in the box:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFLOODMATE 1. 1x BPS100 Pump\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFLOODMATE 2. 1x LSC1.4 Pump\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFLOODMATE 3. 1x WX10 Pump\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFLOODMATE 4. 1x TEM-25H Pump\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePLUS THE FOLLOWING:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e1x 10m Heavy duty rubber power cable\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e1x Phase 1 hose kit: 10m of 25mm (1) non-kink c\/w quick release connectors. For pumping near the property e.g. over window ledges, steps, walls, Hydrosacks, sandbags etc.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e1x Phase 2 hose kit: 10m of 25mm (1) lay flat pipe c\/w quick release connectors. For pumping over flat surfaces e.g. over ground, away from the property.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e2x Hydrosacks\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e1x Easy carry case: including a lid and 2 fastening straps with ABS clips\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCase dimensions 400Wx600Lx420H\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Tsurumi Pumps","offers":[{"title":"FloodMate 1 BPS100","offer_id":47533434929471,"sku":"26-35-1017","price":254.17,"currency_code":"GBP","in_stock":true},{"title":"FloodMate 2 LSC1.4","offer_id":47533434962239,"sku":"26-35-1009","price":779.17,"currency_code":"GBP","in_stock":true},{"title":"FloodMate 3 WX10","offer_id":47533434995007,"sku":"26-35-1011","price":840.83,"currency_code":"GBP","in_stock":true},{"title":"FloodMate 4 TEM-25H","offer_id":47533435027775,"sku":"26-35-1010","price":762.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/0857\/4015\/files\/floodmate-flood-protection-kit-5442-342081.png?v=1718706682"},{"product_id":"garden-irrigation-pump-kit-mvh","title":"Garden Sprinkler Pump Kit for Rivers, Wells \u0026 Rainwater Tanks | APP MVH-10A","description":"\u003ch2\u003eGarden sprinkler pump kit for rivers, wells, lakes and rainwater tanks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eA complete submersible pump kit for running garden sprinklers from clean water in a river, well, tank or water butt.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis FPS Engineered™ kit pairs the APP MVH-10A automatic submersible pump with your choice of 25 m or 30 m of 19 mm bore hose and the fittings to connect it. The pump sits in the water and runs whenever it is submerged, giving a steady, continuous supply that is ideal for sprinklers.\u003c\/p\u003e\n\u003cp\u003ePart of our wider \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/well-and-borehole-pumps\"\u003ewell and borehole pump\u003c\/a\u003e range.\u003c\/p\u003e\n\u003cp\u003eBecause the MVH-10A is controlled by \u003cstrong\u003ewater level, not pressure\u003c\/strong\u003e, it does not start and stop with demand, so it will not cycle the way a pressure pump can on an oscillating sprinkler. That makes it our first choice for sprinkler duty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSprinkler not included\u003c\/strong\u003e, so you can choose the sprinkler or fitting that suits your garden.\u003c\/p\u003e\n\u003cp\u003eIf used with a spray gun, the gun must be left \"open\" whilst ever the pump is running. The pump will not switch off if the gun is closed, and the pump will burn out.\u003c\/p\u003e\n\u003cdiv style=\"margin: 28px 0; padding: 20px 24px; background: #F0EDE5; border-left: 4px solid #283583; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003e\u003cstrong\u003eDo you need an abstraction licence?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eIn England, you are likely to need an abstraction licence from the Environment Agency if you intend to take more than \u003cstrong\u003e20 cubic metres, or 20,000 litres, in a day\u003c\/strong\u003e from a river, stream, lake, pond, canal, reservoir, spring or underground source.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eSmaller abstractions are often exempt, but exemptions have narrowed in recent years, so do not assume, and other permissions may still apply. Always confirm that you have the landowner's permission and that abstraction is lawful and environmentally appropriate for the source. You can \u003ca href=\"https:\/\/www.gov.uk\/guidance\/check-if-you-need-a-licence-to-abstract-water\"\u003echeck whether you need a licence on GOV.UK\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/blogs\/news\/water-abstraction-licences-explained\"\u003e\u003cstrong\u003eRead our guide to water abstraction licences\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAt a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"to9hz3\" data-start=\"7445\" data-end=\"7547\"\u003e\n\u003cstrong data-start=\"7447\" data-end=\"7491\"\u003eDesigned for continuous-flow sprinklers or irrigation:\u003c\/strong\u003e Level-controlled operation avoids demand-based cycling.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"dpw1kf\" data-start=\"7548\" data-end=\"7617\"\u003e\n\u003cstrong data-start=\"7550\" data-end=\"7578\"\u003eStrong pump performance:\u003c\/strong\u003e Up to 110 L\/min and 32 m maximum head.\u003c\/li\u003e\n\u003cli data-section-id=\"atksb7\" data-start=\"7618\" data-end=\"7712\"\u003e\n\u003cstrong data-start=\"7620\" data-end=\"7646\"\u003e19 mm hose:\u003c\/strong\u003e Less restrictive than standard 12.5 mm garden hose.\u003c\/li\u003e\n\u003cli data-section-id=\"3ql89n\" data-start=\"7713\" data-end=\"7813\"\u003e\n\u003cstrong data-start=\"7715\" data-end=\"7755\"\u003eFloat-controlled low-water shut-off:\u003c\/strong\u003e Stops automatically as the surrounding water level falls.\u003c\/li\u003e\n\u003cli data-section-id=\"isnjvo\" data-start=\"7814\" data-end=\"7918\"\u003e\n\u003cstrong data-start=\"7816\" data-end=\"7842\"\u003eHozelock-ready outlet:\u003c\/strong\u003e Connects directly to compatible sprinklers and garden watering accessories.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × APP MVH-10A automatic submersible pump\u003c\/li\u003e\n\u003cli data-section-id=\"1feg93x\" data-start=\"1275\" data-end=\"1326\"\u003e1 × 1\" BSP male × ¾\" BSP male reducing nipple\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1530h9s\" data-start=\"1327\" data-end=\"1385\"\u003e2 × 19 mm hose tail × ¾\" BSP female swivel, straight\u003c\/li\u003e\n\u003cli data-section-id=\"x7583j\" data-start=\"1386\" data-end=\"1445\"\u003e1 × 19 mm hose tail × ¾\" BSP female swivel, 90° elbow\u003c\/li\u003e\n\u003cli data-section-id=\"1vw1lhy\" data-start=\"1446\" data-end=\"1514\"\u003e1 × Hozelock 2170, ¾\" BSP male to female Quick Connect adaptor\u003c\/li\u003e\n\u003cli data-section-id=\"8q9eqf\" data-start=\"1515\" data-end=\"1547\"\u003e2 × stainless-steel hose clips\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSprinkler not included. The supplied Hozelock adaptor provides a female Quick Connect outlet. Check that your chosen sprinkler has a compatible connector.\u003c\/p\u003e\n\u003ch3\u003ePump connections\u003c\/h3\u003e\n\u003cp\u003eThe MVH-10A has a 25 mm (1 inch) screw thread BSP outlet. The supplied 25 mm to 19 mm reducing nipple steps this down to 19 mm, and one of the two hose tails then screws on to suit how you want the hose to leave the pump:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontal outlet:\u003c\/strong\u003e use the straight 19 mm female BSP hose tail so the hose leaves the pump horizontally.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical outlet:\u003c\/strong\u003e use the 19 mm female BSP elbow hose tail where it is better for the hose to rise vertically.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 19 mm hose is pushed fully over the ribbed hose tail and secured with the supplied stainless-steel clip.\u003c\/p\u003e\n\u003ch3\u003eChoose your hose\u003c\/h3\u003e\n\u003cp\u003eBoth hoses are 19 mm bore and rated suitably for the pressure, so either suits the job. The choice comes down to reach and handling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-end=\"334\" data-start=\"312\"\u003e30 m braided hose:\u003c\/strong\u003e The practical choice for everyday domestic garden watering. Lighter and more flexible, it is easier to handle, coil and route around borders, paths and obstacles, while providing an extra 5 metres of reach with only a modest reduction in estimated flow.\u003c\/p\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\" data-end=\"310\" data-start=\"21\"\u003e\u003cstrong data-end=\"49\" data-start=\"21\"\u003e25 m high-pressure hose:\u003c\/strong\u003e The tougher, harder-wearing option for frequent use, commercial applications and grounds maintenance. Its heavy-duty construction offers greater resistance to pressure, abrasion and general wear, while the shorter run provides a slightly higher estimated flow.\u003c\/p\u003e\n\u003ch3\u003eHow it works\u003c\/h3\u003e\n\u003cp\u003eThe MVH-10A is controlled by a \u003cstrong\u003efloat switch\u003c\/strong\u003e. It runs while it is submerged and switches off automatically if the surrounding water level drops. It responds to water level, not to pressure or to a tap being opened or closed, so it gives a steady, continuous flow while running. Power it from a suitable protected 230 V supply.\u003c\/p\u003e\n\u003ch3\u003eImportant: water must discharge continuously\u003c\/h3\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 18px 22px; background: #FBF9F3; border: 1px solid #E5DED8; border-left: 4px solid #E8542B; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003e\u003cstrong style=\"color: #c8431d;\"\u003eThe pump does not stop when the outlet is closed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eThe pump runs when it is powered and the surrounding water raises the float switch. As the water level falls, the float drops and switches the pump off automatically.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eDo not run it against a closed valve, closed nozzle or blocked outlet. If you fit a trigger spray gun, keep it locked open, and switch the pump off at its plug before closing the outlet or disconnecting equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eBecause it runs steadily rather than starting and stopping with demand, the MVH-10A suits \u003cstrong\u003eoscillating, rotating and static sprinklers, open-ended irrigation and continuous watering\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWhere you instead want on-demand operation from a trigger spray gun, a pressure-controlled pump such as the \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/products\/divertron-submersible-well-water-pumps\"\u003eDAB Divertron\u003c\/a\u003e is the better choice.\u003c\/p\u003e\n\u003ch3\u003eExpected performance\u003c\/h3\u003e\n\u003cp\u003eEstimated flow with the hose open and no sprinkler or nozzle fitted. A\u003cspan\u003ectual performance varies with hose length, elevation and the sprinkler fitted.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003e19 mm hose\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eUphill elevation\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eEstimated unrestricted flow\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e25 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 52 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e25 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e5 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 48 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e30 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 49 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e30 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e5 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 45 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #6b7280; line-height: 1.6; margin: 10px 0 0;\"\u003e\u003cem\u003eEstimated using the published MVH-10A curve and Hazen-Williams friction. Figures show estimated flow with the hose discharging freely and no sprinkler fitted. Connecting a sprinkler will reduce the flow and create working pressure at the hose end. Actual performance depends on the sprinkler’s flow requirement, hose length, elevation and fittings.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTechnical specification\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eAPP MVH-10A\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eOperation\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eAutomatic float switch (level-controlled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003ePump type\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eSubmersible clean-water well and irrigation pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eOutlet\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e25 mm (1 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMotor power\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e0.55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e230 V single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum flow\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e110 litres per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum head\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e32 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum submersion depth\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e8 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eWater temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e0°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003ePower cable\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e10 metres with plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e162 × 171 × 461 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e9.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eInstallation and water quality\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in clean water, fully submerged with at least 50 mm of water above the pump for cooling.\u003c\/li\u003e\n\u003cli\u003eKeep the pump clear of the bed to avoid drawing in mud, silt or gravel, and give the float switch room to move freely.\u003c\/li\u003e\n\u003cli\u003eNever lift, lower or suspend the pump by its electrical cable.\u003c\/li\u003e\n\u003cli\u003eProvide suitable electrical protection and keep plugs and connections dry.\u003c\/li\u003e\n\u003cli\u003eMinimum clear well or chamber width: approximately 435 mm, to allow the float switch to operate freely.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 18px 22px; background: #FBF9F3; border: 1px solid #E5DED8; border-left: 4px solid #E8542B; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eClean water only.\u003c\/strong\u003e Water containing sand, silt or abrasive material can damage the pump and invalidate the warranty. This kit is not for sewage, dirty or salt water, or for permanent pond circulation, filtration, fountains or aeration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eUsing untreated water safely\u003c\/h3\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 18px 22px; background: #FBF9F3; border: 1px solid #E5DED8; border-left: 4px solid #E8542B; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003e\u003cstrong style=\"color: #c8431d;\"\u003eThis kit moves water. It does not treat, filter or disinfect it.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eWater taken from rivers, streams, lakes, ponds, wells, tanks and water butts is \u003cstrong\u003enot drinking water\u003c\/strong\u003e. It can contain bacteria, viruses, chemicals, agricultural run-off, algae or other contaminants even when it looks clear. Do not use this pump to supply water for drinking, food preparation or filling drinking-water systems, and assess whether a source is suitable for your intended use before you draw from it.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eBefore pumping from a river, lake or stream\u003c\/h3\u003e\n\u003cp\u003eOwning the pump does not itself give you the right to take water from a natural source. You may need the permission of the landowner, riparian owner or waterbody operator, and environmental or abstraction restrictions may apply. During dry weather or drought, additional restrictions may be introduced to protect flows, habitats and other water users.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/blogs\/news\/can-i-pump-water-from-a-river-or-stream\"\u003e\u003cstrong\u003eRead our guide: Can I pump water from a river or stream?\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4\u003eIs water from this pump safe to drink?\u003c\/h4\u003e\n\u003cp\u003eNo. The kit moves water but does not treat, filter or disinfect it. Water from rivers, ponds, wells, tanks and water butts is not drinking water and can contain bacteria, chemicals or algae even when it looks clear. Do not use it for drinking, food preparation or filling drinking-water systems.\u003c\/p\u003e\n\u003ch4\u003eDoes the pump start and stop automatically?\u003c\/h4\u003e\n\u003cp\u003eIt is controlled by water level, not by demand. It runs whenever it is submerged and switches off automatically if the water level falls below the float switch. It does not start or stop when you open or close a tap or nozzle, so the outlet must stay open while it runs.\u003c\/p\u003e\n\u003ch4\u003eWill it run an oscillating sprinkler?\u003c\/h4\u003e\n\u003cp\u003eIt is well suited to continuous-flow sprinkler duty because it does not switch on and off in response to sprinkler demand. Actual coverage and performance will still depend on the flow and pressure required by the particular sprinkler.\u003c\/p\u003e\n\u003ch4\u003eCan I use it with a trigger spray gun?\u003c\/h4\u003e\n\u003cp\u003eOnly if the gun is kept locked open, because the pump will not stop when you release the trigger. For frequent on and off spray-gun use, a pressure-controlled pump such as the DAB Divertron is more suitable.\u003c\/p\u003e\n\u003ch4\u003eWhat water can it pump?\u003c\/h4\u003e\n\u003cp\u003eClean water only, from wells, rainwater tanks, cisterns, rivers, lakes and water butts. It is not for sandy, silty, dirty or salt water, sewage, ponds or water features.\u003c\/p\u003e","brand":"FPS Engineered™","offers":[{"title":"30m braided hose","offer_id":56350576214395,"sku":"KIT-MVH10A-SPR-30BR","price":360.95,"currency_code":"GBP","in_stock":true},{"title":"25m high-pressure hose","offer_id":56350614258043,"sku":"KIT-MVH10A-SPR-25HP","price":402.62,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/0857\/4015\/files\/Irrigation_Kit_River_Pump_-_clean_Water_4.jpg?v=1784904067"},{"product_id":"divertron-watering-kit","title":"Garden Watering Pump Kit for Spray Guns | DAB Divertron 900","description":"\u003ch2\u003eGarden watering pump kit for spray guns, wells and rainwater tanks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTurn a well, rainwater tank, cistern or storage tank into a powerful, automatic garden watering supply.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis FPS Engineered™ kit pairs the DAB Divertron 900 automatic submersible pump with your choice of 25 m or 30 m of 19 mm diameter hose and a genuine Hozelock Quick Connect outlet.\u003c\/p\u003e\n\u003cp\u003eDrop the pump into a clean water source and click on any compatible spray gun: open the gun and the pump starts on its own, close it and the pump switches off after a short delay. There is no separate pressure switch, controller or manual on\/off to operate.\u003c\/p\u003e\n\u003cp\u003eSpray gun not included, so you can choose the Hozelock-compatible model that suits you.\u003c\/p\u003e\n\u003ch3\u003eAt a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully automatic:\u003c\/strong\u003e starts when the spray gun opens, stops when it closes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrong performance:\u003c\/strong\u003e up to 100 litres per minute and 45 m maximum head.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge-bore 19 mm hose:\u003c\/strong\u003e far less friction loss than standard 12.5 mm garden hose.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine Hozelock outlet:\u003c\/strong\u003e clicks onto any compatible spray gun, nozzle or lance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete kit:\u003c\/strong\u003e pump, hose, brass hose tails, stainless-steel clips and Hozelock adaptor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × DAB Divertron 900 automatic submersible pump \u003c\/li\u003e\n\u003cli\u003e1 x  female hose tail, 1\" BSP tiered with 1\" and 3\/4\" inch hose tails\u003c\/li\u003e\n\u003cli\u003e1 × 15 m H07RN-F power cable with plug\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e1 × female hose tail with ¾ inch connection\u003c\/li\u003e\n\u003cli\u003e2 × correctly sized stainless-steel hose clips\u003c\/li\u003e\n\u003cli\u003e1 × genuine Hozelock 2170 ¾ inch BSP Quick Connect adaptor\u003c\/li\u003e\n\u003cli\u003eEither 25 m of 19 mm high-pressure hose, or 30 m of 19 mm braided hose\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpray gun not included.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat can I use it for?\u003c\/h3\u003e\n\u003cp\u003eBuilt for domestic, commercial and light agricultural watering from clean water, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWatering gardens, allotments and smallholdings from stored rainwater\u003c\/li\u003e\n\u003cli\u003eDrawing clean water from wells, cisterns and storage tanks\u003c\/li\u003e\n\u003cli\u003eHand watering with a spray gun, trigger nozzle or watering lance\u003c\/li\u003e\n\u003cli\u003eNurseries, horticulture and grounds maintenance\u003c\/li\u003e\n\u003cli\u003eOutdoor washdown, and filling cans, containers and troughs\u003c\/li\u003e\n\u003cli\u003eRainwater harvesting and reuse systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFully automatic watering\u003c\/h3\u003e\n\u003cp\u003eThe Divertron 900 has an integrated pressure switch and flow sensor. Open the spray gun and system pressure falls, so the pump starts automatically (cut-in around 2.4 bar). Close the gun and, once flow stops, the pump shuts down after a short delay. A built-in non-return valve holds pressure between uses, and dry-run and thermal protection guard the pump if the water runs low or the motor overheats. In short, it gives the convenience of an outside tap without a separate controller, pressure vessel or manual switching.\u003c\/p\u003e\n\u003ch3\u003eHow the kit connects\u003c\/h3\u003e\n\u003cp\u003eA 1 inch BSP male tiered hose tail (1\" and 3\/4\") screws into the Divertron's outlet, and the 19 mm hose slides over it, secured with a stainless-steel clip.\u003c\/p\u003e\n\u003cp\u003eAt the far end, a second 19 mm hose tail carries a ¾ inch BSP female thread, into which the genuine Hozelock 2170 adaptor screws to give a female Hozelock Quick Connect fitting. Your compatible spray gun then clicks straight in.\u003c\/p\u003e\n\u003cp\u003eThe adaptor is rated to 10 bar, comfortably above the pump's maximum of about 4.5 bar.\u003c\/p\u003e\n\u003ch3\u003eWhy 19 mm hose?\u003c\/h3\u003e\n\u003cp\u003eStandard garden hose is usually only 12.5 mm bore. That is fine on a mains tap, but a long narrow run would throttle a powerful pump like the Divertron 900.\u003c\/p\u003e\n\u003cp\u003eThe supplied 19 mm hose has more than twice the waterway area, so it passes far more water and loses much less pressure over the full 25 or 30 m run, giving stronger spray-gun performance.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThat said, the pump has plenty in reserve. Thanks to its wide operating range (16.7 to 90 litres per minute), you can extend your reach by connecting standard 12.5 mm garden hose to the Hozelock outlet if you need to. On flat ground you can add up to around 25 m of 12.5 mm hose and still get roughly 28 litres per minute at the open end, within the pump's operating range. Narrow hose adds friction quickly, so keep any 12.5 mm section as short as your reach allows.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eExpected performance\u003c\/h3\u003e\n\u003cp\u003eEstimated flow with the hose end fully open and no spray gun fitted:\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\" scope=\"col\"\u003eHose run (19 mm)\u003c\/th\u003e\n\u003cth style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\" scope=\"col\"\u003eUphill lift\u003c\/th\u003e\n\u003cth style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\" scope=\"col\"\u003eEst. flow\u003c\/th\u003e\n\u003cth style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\" scope=\"col\"\u003eRemaining head\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e25 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e67 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e19.9 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e25 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e5 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e64 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e18.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e30 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e63 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e17.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e30 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e5 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e61 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e16.6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #6b7280; line-height: 1.6; margin: 10px 0 0;\"\u003e\u003cem\u003eEstimated with the hose open and no spray gun fitted, using the published Divertron 900 curve and Hazen-Williams friction. \u003cstrong\u003eRemaining head\u003c\/strong\u003e is the pump's maximum head (45 m) minus the uphill lift minus the friction loss at that flow, roughly 10 m of head per bar. Actual performance varies with hose length, elevation, fittings and the spray gun.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; color: #6b7280; line-height: 1.6; margin: 10px 0 0;\"\u003e \u003c\/p\u003e\n\u003cp\u003eWith the gun closed, static pressure at the hose end rises to about 4.2 bar at 2 m of lift and 3.9 bar at 5 m. Maximum flow and maximum pressure do not happen together: with the hose open, flow is highest and pressure at the outlet is near zero; with the gun closed, flow is zero and pressure rises until the pump switches off. Normal spraying sits between the two, drawing on the remaining head shown above.\u003c\/p\u003e\n\u003ch3\u003eUsing a spray gun\u003c\/h3\u003e\n\u003cp\u003eA spray gun works by restricting the flow, and that restriction is what builds the pressure at the nozzle that gives spray reach and pattern. In doing so it reduces the flow rate below the open-hose figures above: pressure and flow trade off, so the tighter the spray setting, the higher the pressure and the lower the flow. What you get depends on the gun's bore, its flow setting, how far the trigger is opened and the spray pattern, and because spray-gun makers rarely publish full flow curves, an exact rate cannot be guaranteed for every gun.\u003c\/p\u003e\n\u003cp\u003eFor comparison, a typical UK outside tap gives roughly 10 to 15 litres per minute at 1 to 3 bar.\u003c\/p\u003e\n\u003cp\u003eThis kit delivers around 61 to 67 litres per minute through an unrestricted hose, at up to about 4.2 bar static, so it is a strong supply for hand watering. It suits hand-held spray guns, trigger nozzles, watering lances, jet, rose and filling attachments, and suitable washdown guns.\u003c\/p\u003e\n\u003ch3\u003eNot for oscillating sprinklers (as a plug-and-play kit)\u003c\/h3\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 18px 22px; background: #FBF9F3; border: 1px solid #E5DED8; border-left: 4px solid #E8542B; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003e\u003cstrong style=\"color: #c8431d;\"\u003eBest used with a hand-operated spray gun or lance.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eA sprinkler's low or fluctuating demand can make the Divertron's flow sensor think watering has stopped, so the pump cycles on and off, which can exceed its permitted starts per hour. The Divertron 900 can run a properly designed sprinkler or irrigation system, but the required flow, pressure and layout must be checked separately first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eChoose your hose\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"312\" data-end=\"334\"\u003e30 m braided hose:\u003c\/strong\u003e The practical choice for everyday domestic garden watering. Lighter and more flexible, it is easier to handle, coil and route around borders, paths and obstacles, while providing an extra 5 metres of reach with only a modest reduction in estimated flow.\u003c\/p\u003e\n\u003cp data-start=\"21\" data-end=\"310\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong data-start=\"21\" data-end=\"49\"\u003e25 m high-pressure hose:\u003c\/strong\u003e The tougher, harder-wearing option for frequent use, commercial applications and grounds maintenance. Its heavy-duty construction offers greater resistance to pressure, abrasion and general wear, while the shorter run provides a slightly higher estimated flow.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhy the DAB Divertron 900?\u003c\/h3\u003e\n\u003cp\u003eThe Divertron 900 brings the convenience of a domestic pressure system to a fully submersible pump. It sits quietly inside the well or tank and responds whenever the spray gun is opened, with no surface pump, external controller or pressure switch to install. Its multi-stage hydraulics deliver the pressure needed for spraying while keeping good flow through the large-bore hose. It is built from corrosion-resistant technopolymer with stainless-steel internals, with an IP68 motor, thermal and dry-run protection and an integrated non-return valve.\u003c\/p\u003e\n\u003ch3\u003eTechnical specification\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\" scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\" scope=\"col\"\u003eDAB Divertron 900\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum flow\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e100 litres per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum head\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e45 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum pump pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 4.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eRecommended operating range\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e\n\u003cp\u003e1 to 5.4 m³\/h\u003c\/p\u003e\n\u003cp\u003e(16.7 L\/min - 90 L\/min)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003ePump outlet\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e1 inch female BSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMotor input power\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e920 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMotor rating\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e0.75 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e230 V single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eAutomatic cut-in pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 2.4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum immersion depth\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e12 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum permitted starts\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e20 per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMotor protection\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eInsulation class\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eWater temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e0°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum pump diameter\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e160 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003ePump height\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e596 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003ePump weight\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003ePower cable\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e15 metres with plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eInstallation and water quality\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in clean water, fully submerged with at least 50 mm of water above the pump for cooling.\u003c\/li\u003e\n\u003cli\u003eIn a well, sit it at least 1 m above the bottom to avoid drawing in sand or silt.\u003c\/li\u003e\n\u003cli\u003eSupport the pump properly and never suspend or lift it by its electrical cable.\u003c\/li\u003e\n\u003cli\u003eAllow clearance around the 160 mm pump body.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 18px 22px; background: #FBF9F3; border: 1px solid #E5DED8; border-left: 4px solid #E8542B; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eClean water only.\u003c\/strong\u003e Water containing sand, silt or abrasive material can damage the pump and invalidate the warranty. This kit is not for sewage, dirty or salt water, pond circulation or water features.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4\u003eDoes the pump start automatically when I open the spray gun?\u003c\/h4\u003e\n\u003cp\u003eYes. The Divertron 900 has an integrated pressure switch and flow sensor. Opening the gun drops the pressure and starts the pump; closing it stops the pump after a short delay. There is nothing to switch on and off.\u003c\/p\u003e\n\u003ch4\u003eIs a spray gun included?\u003c\/h4\u003e\n\u003cp\u003eNo. The kit finishes in a genuine Hozelock Quick Connect fitting, so you can add any compatible spray gun, nozzle or lance you prefer.\u003c\/p\u003e\n\u003ch4\u003eCan I use my own 12.5 mm garden hose instead?\u003c\/h4\u003e\n\u003cp\u003eWe do not recommend it. Narrow garden hose sharply increases friction and would waste much of the pump's flow. The supplied 19 mm hose is what makes the kit perform.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"FPS Engineered™","offers":[{"title":"30m braided hose","offer_id":56352759906683,"sku":"DIV-900-KIT-HZLCK-1","price":454.67,"currency_code":"GBP","in_stock":true},{"title":"25m high-pressure hose","offer_id":56352759939451,"sku":"DIV-900-KIT-HZLCK-2","price":496.34,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/0857\/4015\/files\/DAB_Divertron_Watering_Kit.jpg?v=1785740590"},{"product_id":"small-flood-pump-kit-spp2-puddle-pump","title":"Small Flood Pump Kit | SPP2 Puddle Pump","description":"\u003ch2\u003eSmall home flood pump kit for garages, cellars and utility rooms\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEverything you need to clear a small flood yourself, ready to deploy the moment water appears.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis FPS Engineered™ kit pairs the Stream SPP2-4 puddle pump with your choice of 6 m or 10 m of 25 mm reinforced suction and delivery hose, the fittings to connect it. Drop the pump into the water, run the hose to a safe discharge point and switch on at the plug.\u003c\/p\u003e\n\u003cp\u003eThe SPP2-4 clears standing water down to approximately 2mm, so it takes a floor back to damp rather than leaving an inch behind. It is the entry-level choice for a homeowner who will be there to deploy the pump and supervise it.\u003c\/p\u003e\n\u003cp\u003ePart of our wider \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/flood-control\"\u003eflood defence\u003c\/a\u003e and \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/puddle-pumps\"\u003epuddle pump\u003c\/a\u003e ranges.\u003c\/p\u003e\n\u003ch3\u003eAttended use only\u003c\/h3\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 18px 22px; background: #FBF9F3; border: 1px solid #E5DED8; border-left: 4px solid #E8542B; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003e\u003cstrong style=\"color: #c8431d;\"\u003eThis pump is manual. It has no float switch and will not stop on its own.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eThe SPP2-4 runs for as long as it is powered. Once the water is gone it will continue to run dry, and running dry will damage the pump.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eStay with the pump while it is working and switch it off at the plug as soon as the water is cleared. Do not leave it running overnight, do not leave it as a standby pump in an empty sump, and do not rely on it to protect an unoccupied property. If you need unattended or automatic protection, choose a pump with a float switch from our \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/sump-pumps\"\u003esump pump\u003c\/a\u003e or \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/basement-waterproofing-pumps\"\u003ebasement waterproofing\u003c\/a\u003e ranges.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAt a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClears down to approximately 2 mm:\u003c\/strong\u003e Removes standing water that a conventional submersible pump leaves behind.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReady to use out of the box:\u003c\/strong\u003e Pump, hose, fittings, clip with nothing else to buy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight enough to carry and deploy:\u003c\/strong\u003e 3 kg and 250 mm tall, so it fits under appliances and into shallow corners.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReinforced 25 mm hose:\u003c\/strong\u003e Holds its shape around door thresholds and up steps without kinking and cutting the flow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandles slightly dirty flood water:\u003c\/strong\u003e Passes solids up to 3 mm, so grit and light debris will not immediately block it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Stream SPP2-4 submersible puddle pump, with 10 m power cable and plug fitted\u003c\/li\u003e\n\u003cli\u003e1 × 25 mm reinforced suction and delivery hose, 6 m or 10 m, to suit your chosen length\u003c\/li\u003e\n\u003cli\u003e1 × 25 mm hose tail, 90° elbow\u003c\/li\u003e\n\u003cli\u003e1 × 20 to 32 mm stainless-steel hose clip\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe pump is also supplied with its own set of three straight hose tails, in 12 mm, 19 mm and 25 mm, so you retain the option of running a smaller bore hose later.\u003c\/p\u003e\n\u003ch3\u003eHow the kit connects\u003c\/h3\u003e\n\u003cp\u003eThe SPP2-4 has a 25 mm outlet on top of the pump. The supplied 90° elbow hose tail screws in and turns the flow sideways, so the hose runs away along the floor instead of standing straight up. Both options are useful depending on the pump use situation.\u003c\/p\u003e\n\u003cp\u003ePush the 25 mm hose fully over the ribbed tail and tighten the supplied stainless-steel clip. If you prefer the hose to leave vertically, use the straight 25 mm tail supplied with the pump instead.\u003c\/p\u003e\n\u003ch3\u003eChoose your hose\u003c\/h3\u003e\n\u003cp\u003eBoth lengths are 25 mm bore reinforced suction and delivery hose, which resists kinking and can be run up steps or over a threshold. The choice comes down to how far the water has to travel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6 m hose:\u003c\/strong\u003e The right length for a single garage, utility room, conservatory or patio where the discharge point is just outside the door. Shorter means less to coil, less to store and slightly higher flow.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e10 m hose:\u003c\/strong\u003e The safer choice for a cellar, a basement with a flight of steps, or anywhere you need to get the water well clear of the building before releasing it. The extra 4 m costs only a few litres per minute and is far more useful than running short.\u003c\/p\u003e\n\u003cp\u003eDischarge the water somewhere it will drain away and not simply return to the building or run onto a neighbouring property.\u003c\/p\u003e\n\u003ch3\u003eExpected performance\u003c\/h3\u003e\n\u003cp\u003eEstimated flow with the hose discharging freely. Uphill lift is measured from the water surface to the point where the hose discharges, so a cellar with a flight of steps is typically 2 m to 3 m.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003e25 mm hose\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eUphill lift\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eEstimated flow\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e6 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e1 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 55 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e6 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 50 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e6 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e3 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 43 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e10 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e1 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 52 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e10 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 46 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e10 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e3 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 40 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #6b7280; line-height: 1.6; margin: 10px 0 0;\"\u003e\u003cem\u003eEstimated using the published SPP2-4 curve and Hazen-Williams friction, with the hose discharging freely. Around 50 litres per minute clears roughly 3,000 litres, or 3 cubic metres, in an hour. Flow falls as the water level drops towards the last few millimetres. Actual performance depends on hose length, lift, fittings and how the hose is routed.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTechnical specification\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eStream SPP2-4\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eOperation\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eManual only, no float switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003ePump type\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eSubmersible puddle pump, clean and slightly dirty water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMinimum water level\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApproximately 2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eOutlet\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMotor power\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e0.1 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e230 V single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum flow\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e70 litres per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum head\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e6 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eFree passage\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum submersion depth\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e5 metres, can also be use partially submerged.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eWater temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e5°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003ePower cable\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e10 metres with plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e135 × 155 × 250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e2 years, manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWhat can I use it for?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eClearing surface water from garages, utility rooms, conservatories and porches\u003c\/li\u003e\n\u003cli\u003ePumping out a flooded cellar or basement while you are there to supervise\u003c\/li\u003e\n\u003cli\u003eDraining flat roofs, light wells, stairwells and outside basement steps\u003c\/li\u003e\n\u003cli\u003eRemoving standing water from patios, driveways and low-lying paths\u003c\/li\u003e\n\u003cli\u003eEmptying water storage containers, and unoccupied hot tubs once the water has cooled\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUsing it in a flood\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate the electricity to the flooded area before you enter it, and never stand in water to reach a socket or switch.\u003c\/li\u003e\n\u003cli\u003ePlug the pump into a socket well away from the water and keep the plug and any connections dry and off the floor.\u003c\/li\u003e\n\u003cli\u003eSet the pump on the flattest, lowest part of the floor, clear of silt and debris, and run the hose out before switching on.\u003c\/li\u003e\n\u003cli\u003eWatch the discharge. If the flow drops away, switch off at the plug and check the inlet for debris rather than letting the pump labour.\u003c\/li\u003e\n\u003cli\u003eSwitch off at the plug as soon as the water is cleared, then flush the pump through with clean water before storing it dry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"border: 1px solid #e2e6ea; border-radius: 8px; padding: 18px 20px; margin: 24px 0; background: #f8fafc;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #0b5390; font-size: 13px; letter-spacing: 0.04em; text-transform: uppercase; margin-bottom: 6px;\"\u003eRecommended add-on for cellars and raised discharge\u003c\/div\u003e\n\u003cdiv style=\"font-size: 19px; font-weight: bold; color: #13212b; margin-bottom: 8px;\"\u003eNon-Return Valve and Hose Tail Kit, 1\" BSP 25mm\u003c\/div\u003e\n\u003cdiv style=\"color: #2b3640; line-height: 1.65; margin-bottom: 10px;\"\u003eFits between the pump outlet and the hose, and holds the water in the hose when you switch off. Without one, everything standing in a 10 metre run drains straight back through the pump and onto the floor you have just cleared, which matters most when you are lifting up cellar steps or over a wall. It also keeps the pump from having to shift the same water twice if you switch off and on again as the level drops. Supplied as a matched valve and 25mm hose tail, so it screws directly into the SPP2-4 outlet with no additional fittings.\u003c\/div\u003e\n\u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/products\/non-return-valve-hose-tail-kit-1-bsp-25mm\" style=\"display: inline-block; background: #0B5390; color: #fff; text-decoration: none; font-weight: bold; padding: 10px 18px; border-radius: 6px;\"\u003eView the non-return valve kit\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWater quality limits\u003c\/h3\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 18px 22px; background: #FBF9F3; border: 1px solid #E5DED8; border-left: 4px solid #E8542B; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eClean and slightly dirty water only.\u003c\/strong\u003e The SPP2-4 passes solids up to 3 mm. Sand, silt, grit and abrasive material will wear it and can invalidate the warranty. This kit is not for sewage or salt water, and is not intended for ponds, water features or permanent installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4\u003eDoes the pump switch off on its own?\u003c\/h4\u003e\n\u003cp\u003eNo. The SPP2-4 is manual only and has no float switch. It runs for as long as it is powered, so you need to be there to switch it off at the plug when the water is cleared. Leaving it to run dry will damage it.\u003c\/p\u003e\n\u003ch4\u003eCan I leave it in a sump as standby protection?\u003c\/h4\u003e\n\u003cp\u003eNo. This kit is for attended emergency use. For automatic or unattended protection, choose a pump with a float switch from our \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/sump-pumps\"\u003esump pump\u003c\/a\u003e range.\u003c\/p\u003e\n\u003ch4\u003eHow low will it pump?\u003c\/h4\u003e\n\u003cp\u003eDown to approximately 2 mm, which is why a puddle pump suits a flat floor. A conventional submersible pump typically leaves a much deeper layer behind, so the last of the water has to be mopped or squeegeed out.\u003c\/p\u003e\n\u003ch4\u003eWhich hose length should I choose?\u003c\/h4\u003e\n\u003cp\u003eChoose 6 m if the discharge point is immediately outside the affected room. Choose 10 m for a cellar, a flight of steps, or anywhere the water needs to be released well clear of the building. The longer hose costs only a few litres per minute.\u003c\/p\u003e\n\u003ch4\u003eCan I use my own garden hose instead?\u003c\/h4\u003e\n\u003cp\u003eYou can, using one of the smaller hose tails supplied with the pump, but a 12.5 mm garden hose will roughly halve the flow and is prone to kinking on stairs and thresholds. The 25 mm reinforced hose in this kit is what lets the pump clear water at a useful rate.\u003c\/p\u003e\n\u003ch4\u003eWill it handle silty or muddy water?\u003c\/h4\u003e\n\u003cp\u003eIt will pass particles up to 3 mm in suspension, so it copes with typical flood water carrying grit and light debris. It is not a solids-handling or sewage pump, and continuous use in gritty water will shorten its life. Keep the pump off the worst of the silt where you can.\u003c\/p\u003e\n\u003ch4\u003eCan I use it to empty a hot tub?\u003c\/h4\u003e\n\u003cp\u003eYes, provided the tub is unoccupied and the water has been allowed to cool to below 40°C. Flush the pump through with clean water afterwards to clear any treatment chemicals.\u003c\/p\u003e","brand":"FPS Engineered™","offers":[{"title":"6m Suction \u0026 Delivery hose","offer_id":56358115377531,"sku":"SPP2-4-KIT-FLOOD-1-06","price":128.58,"currency_code":"GBP","in_stock":true},{"title":"10m Suction \u0026 Delivery hose","offer_id":56358115410299,"sku":"SPP2-4-KIT-FLOOD-1-10","price":141.08,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/0857\/4015\/files\/SPP2_Small_Flood_Kit.jpg?v=1785420283"},{"product_id":"hot-tub-emptying-pump-kit","title":"Hot Tub Draining Pump Kit | SPP2 Puddle Pump","description":"\u003ch2\u003eHot tub emptying pump kit for hot tubs, spas and swim spas\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDrains a 5-6 person hot tub in about 25 minutes and takes the water down to almost nothing.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis FPS Engineered™ kit pairs the Stream SPP2-4 puddle pump with 6 m of 25 mm reinforced hose and the fittings to connect it. Sit the pump on the floor of the tub, run the hose over the side to a drain and switch on.\u003c\/p\u003e\n\u003cp\u003eMost hot tubs have drains that don't function well. The built-in gate valve dribbles for an hour and then leaves several centimetres of water sitting in the footwell. This pump clears a 1,500 litre tub in around 25 minutes and takes it down to approximately 2 mm, so there is very little left to sponge out before you wipe the shell down.\u003c\/p\u003e\n\u003cp\u003ePart of our wider \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/puddle-pumps\"\u003epuddle pump\u003c\/a\u003e range.\u003c\/p\u003e\n\u003ch3\u003eLet the water cool first\u003c\/h3\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 18px 22px; background: #FBF9F3; border: 1px solid #E5DED8; border-left: 4px solid #E8542B; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003e\u003cstrong style=\"color: #c8431d;\"\u003eMaximum water temperature is 40°C. Most hot tubs run at 37°C to 40°C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eThat puts a tub at operating temperature right at the top of the pump's limit. Switch the heater off, take the cover off and let the water cool before you pump. Warm is fine, hot is not.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eThe pump is also manual, with no float switch, so it will not stop on its own. Stay with it and switch off at the plug as soon as the tub is empty. Running dry will damage it.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAt a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAround 25 minutes for a typical tub:\u003c\/strong\u003e 70 litres per minute at the modest lift a tub wall presents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrains to approximately 2 mm:\u003c\/strong\u003e Leaves the footwell nearly dry rather than ankle deep.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits in the footwell:\u003c\/strong\u003e 135 mm wide and 3 kg, so it sits flat on the shell and lifts out one-handed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6 m of reinforced hose:\u003c\/strong\u003e Enough to reach a gully or drain and stiff enough to hold its shape over the tub side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandles treated water:\u003c\/strong\u003e Suitable for chlorinated and brominated water, provided you flush it through afterwards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Stream SPP2-4 submersible puddle pump, with 10 m power cable and plug fitted\u003c\/li\u003e\n\u003cli\u003e1 × 6 m length of 25 mm reinforced suction and delivery hose\u003c\/li\u003e\n\u003cli\u003e1 × 20 to 32 mm stainless-steel hose clip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe pump is supplied with its own set of three straight hose tails, in 12 mm, 19 mm and 25 mm. The 25 mm tail is the one this kit uses.\u003c\/p\u003e\n\u003ch3\u003eHow the kit connects\u003c\/h3\u003e\n\u003cp\u003eThe SPP2-4 has a 25 mm outlet on top of the pump, and the 25 mm straight hose tail supplied with the pump screws into it. Push the hose fully onto the ribbed tail and tighten the supplied stainless-steel clip.\u003c\/p\u003e\n\u003cp\u003eThe hose then runs straight up from the pump and over the side of the tub. Drop the far end to your discharge point.\u003c\/p\u003e\n\u003ch3\u003eHow long will it take?\u003c\/h3\u003e\n\u003cp\u003eEstimated with 6 m of hose discharging freely. Lift is measured from the water surface up to the top of the tub side, so most domestic tubs sit between 0.5 m and 1 m.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eTub volume\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eLift over the side\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eEstimated flow\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eEstimated time\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e1,000 litres\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e0.5 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 59 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 17 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e1,500 litres\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e0.5 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 59 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 25 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e1,500 litres\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e1 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 57 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 26 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e2,000 litres\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e1 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 57 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 35 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #6b7280; line-height: 1.6; margin: 10px 0 0;\"\u003e\u003cem\u003eEstimated using the published SPP2-4 curve and Hazen-Williams friction, with the hose discharging freely. Flow tails off over the last few centimetres as the water level drops towards the pump. Actual times depend on tub volume, lift and how the hose is routed. A typical four to six seater domestic tub holds roughly 1,200 to 1,800 litres; check your manufacturer's figure.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTechnical specification\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eStream SPP2-4\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eOperation\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eManual only, no float switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003ePump type\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eSubmersible puddle pump, clean and slightly dirty water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMinimum water level\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApproximately 2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eOutlet\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMotor power\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e0.1 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e230 V single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum flow\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e70 litres per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum head\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e6 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eFree passage\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eWater temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e5°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum submersion depth\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e5 metres, can be partially submerged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003ePower cable\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e10 metres with plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e135 × 155 × 250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e2 years, manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to empty your hot tub\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSwitch off the heater and the tub's power at the isolator, take the cover off, and let the water cool to below 40°C.\u003c\/li\u003e\n\u003cli\u003eStop dosing chemicals a few days beforehand if you plan to discharge onto a lawn or border, so the chlorine or bromine level has fallen.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSit the pump flat in the deepest part of the footwell, away from the suction fittings and skimmer.\u003c\/li\u003e\n\u003cli\u003eRun the hose up and over the side to your discharge point.\u003c\/li\u003e\n\u003cli\u003ePlug into a socket well clear of the water. Keep the plug and any connection dry and off the ground.\u003c\/li\u003e\n\u003cli\u003eSwitch on and stay with it. Move the pump to the lowest point as the level drops to clear the last of the water.\u003c\/li\u003e\n\u003cli\u003eSwitch off at the plug the moment the water is gone, then flush the pump and hose through with clean water before storing them dry.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eWhere to discharge the water\u003c\/h3\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 20px 24px; background: #F0EDE5; border-left: 4px solid #283583; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003e\u003cstrong\u003eTreated hot tub water is not the same as rainwater.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eChlorine and bromine will scorch grass and can harm plants, and neither should reach a pond, stream or ditch, where it is toxic to fish and invertebrates. The usual advice is to stop dosing a few days before you drain, then test that the level has dropped before discharging anywhere near planting.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eA foul drain or the household sewer is the safest destination. Do not discharge to a surface water drain, which in most cases runs directly to a watercourse. If your tub uses a saltwater or bromine system, or you are unsure which drain is which, check with your water company first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWater quality limits\u003c\/h3\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 18px 22px; background: #FBF9F3; border: 1px solid #E5DED8; border-left: 4px solid #E8542B; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eClean and slightly dirty water only.\u003c\/strong\u003e The SPP2-4 handles normally treated hot tub water, but it is not a chemical-resistant pump. Flush it through with clean water after every use so treatment chemicals are not left standing inside it. It is not for salt water, sewage or heavily soiled water, and grit will wear it.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4\u003eHow long does it take to empty a hot tub?\u003c\/h4\u003e\n\u003cp\u003eAround 25 minutes for a typical 1,500 litre tub, and about 35 minutes for a larger 2,000 litre one. \u003c\/p\u003e\n\u003ch4\u003eWill it get all the water out?\u003c\/h4\u003e\n\u003cp\u003eIt clears down to approximately 2 mm, so you are left with a damp shell rather than a footwell full of water. Moving the pump to the lowest point as the level drops helps it pick up the last of it.\u003c\/p\u003e\n\u003ch4\u003eCan I pump the water while it is still hot?\u003c\/h4\u003e\n\u003cp\u003eNo. The limit is 40°C and most tubs run at 37°C to 40°C, which leaves no margin. Switch the heater off and let it cool first.\u003c\/p\u003e\n\u003ch4\u003eIs it safe with chlorinated or brominated water?\u003c\/h4\u003e\n\u003cp\u003eYes for normal bathing concentrations, provided you flush the pump and hose through with clean water afterwards. It is not a chemical-resistant pump, so do not use it to move concentrated chemicals or shock-dosed water. For repeated duty in chemically treated water, a \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/chemical-resistant-water-pumps\"\u003echemical-resistant pump\u003c\/a\u003e is the better choice.\u003c\/p\u003e\n\u003ch4\u003eDoes the pump switch off on its own?\u003c\/h4\u003e\n\u003cp\u003eNo. It is manual, with no float switch, so it runs until you switch it off at the plug. Do not leave it unattended, because running dry will damage it.\u003c\/p\u003e\n\u003ch4\u003eWhich hose tail does it use?\u003c\/h4\u003e\n\u003cp\u003eThe 25 mm straight tail supplied with the pump, which lets the hose run vertically up and out of the tub. The 12 mm and 19 mm tails are also in the box if you ever want to run a narrower hose, though flow will drop.\u003c\/p\u003e\n\u003ch4\u003eCan I use the same kit for a swim spa or a paddling pool?\u003c\/h4\u003e\n\u003cp\u003eYes for both, though a swim spa holds several times more water than a hot tub, so allow proportionally longer. For emptying a full swimming pool, our \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/swimming-pool-pumps\"\u003eswimming pool\u003c\/a\u003e range has a higher-flow option better suited to the volume.\u003c\/p\u003e\n\u003ch4\u003eCan I use it to clear a flood as well?\u003c\/h4\u003e\n\u003cp\u003eYes, it is the same pump we supply in our flood kits. This kit has a 6 m hose sized for a garden discharge point, so if flood clearance is the main job, the 10 m option in the flood kit gives you more reach.\u003c\/p\u003e","brand":"FPS Engineered™","offers":[{"title":"Default Title","offer_id":56359160873339,"sku":"SPP2-4-KIT-HOTTUB-1","price":125.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/0857\/4015\/files\/SPP2_Puddle_Pump_for_hot_tub_drainage.jpg?v=1785747495"},{"product_id":"swimming-pool-drainage-pump-kit","title":"Swimming Pool Draining Pump Kit | Mizar 60 Submersible Pump","description":"\u003ch2\u003eSwimming pool drainage pump kit for emptying pools, spas and swim spas\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEmpties a domestic swimming pool at around 130 litres per minute, in water that would corrode an ordinary pump.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis FPS Engineered™ kit pairs the Mizar submersible pump with 10m of 32mm reinforced suction and delivery hose, a 32mm male hose tail and a stainless-steel clip. Lower the pump to the deepest point of the pool, run the hose to your discharge point and switch on.\u003c\/p\u003e\n\u003cp\u003eThe Mizar 60 is built from \u003cspan\u003e\u003cstrong\u003ehigh-grade\u003c\/strong\u003e \u003c\/span\u003e\u003cstrong\u003e304 stainless steel\u003c\/strong\u003e, which is the grade that resists chlorides. That matters here, because pool water is exactly the liquid that pits ordinary stainless steel and rusts cast iron. Even so, the pump must be rinsed through with fresh water after every use. Read more in our \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/blogs\/news\/chemical-resistant-pumps-materials-guide\"\u003eguide to chemical resistant pump materials\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePart of our wider \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/chemical-resistant-water-pumps\"\u003echemical resistant pump\u003c\/a\u003e range.\u003c\/p\u003e\n\u003ch3\u003eThis is a drainage pump, not a pool pump\u003c\/h3\u003e\n\u003cdiv style=\"margin: 28px 0; padding: 20px 24px; background: #F0EDE5; border-left: 4px solid #283583; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003e\u003cstrong\u003eTwo completely different jobs, two completely different pumps.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003e\u003cstrong\u003eCirculation and filtration pumps\u003c\/strong\u003e keep the water in the pool clean. They sit dry alongside the pool, draw water through a suction line, push it through the filter and return it. They are plumbed permanently into the pool's pipework, sized to turn the whole pool over every eight hours or so, and they run day in, day out against the back pressure of a filter. If your water has gone cloudy, your pump is noisy, or you are replacing an existing unit, that is what you need. Browse our \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/swimming-pool-pumps\"\u003eswimming pool pumps\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eDrainage pumps\u003c\/strong\u003e empty the pool. This one is submersible, portable and manually switched, and it discharges to waste rather than through a filter. You use it for a handful of hours once a season, to drop the level for repairs, to empty for winter, or to clear a pool that has been left standing. It cannot be plumbed into a filtration circuit and it will not replace your pool pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAttended use only\u003c\/h3\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 18px 22px; background: #FBF9F3; border: 1px solid #E5DED8; border-left: 4px solid #E8542B; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003e\u003cstrong style=\"color: #c8431d;\"\u003eThe Mizar 60 in this kit is manual. It has no float switch and will not stop on its own.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eThat is deliberate. A float switch would cut the pump off well before the pool was empty, which defeats the purpose. The trade-off is that you have to be there, and emptying a full pool is not a quick job. Budget several hours and check on it periodically.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eSwitch off at the plug once the water stops flowing. Running dry will damage the pump. Do not leave it running unattended or overnight.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAt a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAround 130 litres per minute:\u003c\/strong\u003e Through the 10 m of 32 mm hose supplied, at a typical 2 m lift.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAISI 304 stainless steel:\u003c\/strong\u003e The grade that resists chlorides, so it handles chlorinated and salt-chlorinated water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10mm free passage:\u003c\/strong\u003e Passes leaves, grit and light debris from a pool that has been left standing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge-bore 32mm hose:\u003c\/strong\u003e Reinforced, so it holds its shape over the pool edge and up steps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRinse through after every use:\u003c\/strong\u003e Two minutes in clean water is all it takes, and it is what keeps the pump serviceable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Mizar 60 submersible pump, 230 V, manual, AISI 304 stainless steel\u003c\/li\u003e\n\u003cli\u003e1 × 10 m length of 32 mm reinforced suction and delivery hose\u003c\/li\u003e\n\u003cli\u003e1 × 32 mm male hose tail\u003c\/li\u003e\n\u003cli\u003e1 × stainless-steel hose clip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHow the kit connects\u003c\/h3\u003e\n\u003cp\u003eThe Mizar 60 has a female 32 mm outlet. The supplied 32 mm male hose tail screws straight into it, and the hose pushes fully over the ribbed end of the tail and is secured with the stainless-steel clip. The far end of the hose runs open to your discharge point, so there is nothing to connect there.\u003c\/p\u003e\n\u003cp\u003eGet the discharge end lower than the water level in the pool if you can. Once the hose is full, gravity does some of the work for you, and on a long drain that is worth having. It also means that when you switch off, the water standing in the hose will run out rather than back into the pool.\u003c\/p\u003e\n\u003ch3\u003eExpected performance\u003c\/h3\u003e\n\u003cp\u003eEstimated flow through the supplied 10m of 32mm hose. Uphill lift is measured from the water surface to the point where the hose discharges, so most pools sit between 1 m and 3 m.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eUphill lift\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eEstimated flow\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003e20,000 litres\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003e40,000 litres\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e1 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 138 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 2.4 hours\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 4.8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 130 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 2.6 hours\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 5.1 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e3 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 121 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 2.8 hours\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 5.5 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow long will my pool take?\u003c\/h3\u003e\n\u003cp\u003eWork out your volume in litres by multiplying length × width × average depth in metres, then multiplying by 1,000. Typical UK pools, at a 2 m lift:\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003ePool\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eApproximate volume\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eEstimated time\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eAbove-ground, 12 ft round, 0.9 m deep\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e9,000 litres\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 1.2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eSmall in-ground, 6 × 3 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e22,000 litres\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 2.8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eTypical in-ground, 8 × 4 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e45,000 litres\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 5.8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eLarge in-ground, 10 × 5 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e75,000 litres\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 9.6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #6b7280; line-height: 1.6; margin: 10px 0 0;\"\u003e\u003cem\u003eEstimated using the published Mizar 60 curve and Hazen-Williams friction for 32 mm bore, with the hose discharging freely. Flow tails off as the level drops and the lift increases, so a deep pool takes slightly longer than the average figure suggests. Actual times depend on pool volume, lift, hose routing and any limit on how fast you can discharge. On a larger pool, plan the drain across two sessions rather than one very long one.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTechnical specification\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eMizar 60\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eOperation\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eManual only, no float switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003ePump type\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eSubmersible chemical resistant, clean and slightly dirty water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaterial\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e\n\u003cspan\u003ehigh-grade \u003c\/span\u003e304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eOutlet\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e32 mm female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMotor power\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e0.45 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e230 V single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum flow\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e175 litres per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum head\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e10 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eFree passage\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e154 × 154 × 234 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e5.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e2 years, manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to drain your pool\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eStop dosing chemicals several days beforehand and let the chlorine or bromine level fall, then test it before you pump.\u003c\/li\u003e\n\u003cli\u003eCheck where the water is going and confirm it is allowed. See the discharge guidance below.\u003c\/li\u003e\n\u003cli\u003eLower the pump to the deepest point of the pool, clear of the main drain and away from any sediment on the floor.\u003c\/li\u003e\n\u003cli\u003eRun the hose to your discharge point, getting the open end as low as you can.\u003c\/li\u003e\n\u003cli\u003ePlug into an socket well clear of the water, keeping the plug dry and off the ground.\u003c\/li\u003e\n\u003cli\u003eSwitch on and monitor. Check on the discharge periodically and watch the level as it drops.\u003c\/li\u003e\n\u003cli\u003eSwitch off at the plug as soon as the flow stops. Do not let it run dry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRinse the pump and hose through with clean fresh water before you put them away.\u003c\/strong\u003e This step is not optional. See below.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eRinse the pump through after every use\u003c\/h3\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 18px 22px; background: #FBF9F3; border: 1px solid #E5DED8; border-left: 4px solid #E8542B; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003e\u003cstrong style=\"color: #c8431d;\"\u003eThis is the single most important thing you can do to keep the pump serviceable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eChlorine, bromine and salt do their damage over time, not in the few hours the pump is running. What causes problems is treated water left sitting inside the pump body and hose while it is in storage, where it concentrates as it evaporates and attacks seals, the shaft and eventually even 316 stainless. A pump put away wet after one drain can be pitted by the time you next need it.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003e\u003cstrong\u003eHow to do it.\u003c\/strong\u003e Stand the pump in a bucket, water butt or trug of clean fresh water, deep enough to cover the inlet, and run it for two or three minutes with the hose discharging to waste. That flushes fresh water through the impeller, the body and the full length of the hose. Then lift it out, let it drain fully, and store it dry with the hose uncoiled or loosely coiled so no water is trapped in it.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eDo the same after a saltwater pool, where it matters more. Corrosion damage caused by treated water left standing in the pump is not a manufacturing fault and is not covered by the warranty.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWhere to discharge the water\u003c\/h3\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 18px 22px; background: #FBF9F3; border: 1px solid #E5DED8; border-left: 4px solid #E8542B; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003e\u003cstrong style=\"color: #c8431d;\"\u003eA full pool is tens of thousands of litres of treated water. Where it goes matters.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eChlorinated water must not reach a stream, river, ditch, pond or surface water drain. Chlorine is acutely toxic to fish and invertebrates, and a surface water drain in most cases discharges straight to a watercourse. Doing so can be an offence.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eStop dosing several days before you drain and let the chlorine level fall, then test it. Levels below around 0.05 mg\/l are generally considered safe for the environment, and sunlight will bring an untreated pool down over a few days. A neutralising agent will do it faster.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eThe foul sewer is normally the right destination, but a domestic connection cannot take 45,000 litres at 130 litres per minute without risk of backing up. Drain in stages, throttle the flow if you can, or spread the water slowly over your own grass or planted ground once dechlorinated. For salt-chlorinated pools, or anything above domestic scale, check with your water company before you start.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4\u003eDo I really need to rinse the pump out after using it?\u003c\/h4\u003e\n\u003cp\u003eYes, every time. Treated water left standing inside the pump concentrates as it evaporates and attacks the seals and shaft, and given long enough it will pit even 316 stainless. Stand the pump in a bucket of clean fresh water and run it for two or three minutes with the hose discharging to waste, then let it drain and store it dry. Corrosion from treated water left inside the pump is not covered by the warranty.\u003c\/p\u003e\n\u003ch4\u003eWill this pump run my pool's filtration system?\u003c\/h4\u003e\n\u003cp\u003eNo. Filtration needs a surface-mounted circulation pump plumbed into the pool's pipework and sized to turn the water over against the resistance of your filter. This is a portable submersible pump for emptying to waste. See our \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/swimming-pool-pumps\"\u003eswimming pool pumps\u003c\/a\u003e for circulation and filtration.\u003c\/p\u003e\n\u003ch4\u003eHow long will it take to empty my pool?\u003c\/h4\u003e\n\u003cp\u003eJust under six hours for a typical 8 × 4 m in-ground pool, and about three hours for a small 6 × 3 m one. Multiply length × width × average depth in metres, then by 1,000, to get your volume in litres, and divide by 130 litres per minute.\u003c\/p\u003e\n\u003ch4\u003eDo I need any other fittings?\u003c\/h4\u003e\n\u003cp\u003eNo. The pump has a female 32 mm outlet and the kit supplies the matching male hose tail and clip, so it connects with nothing else to buy. If you later want to extend the run, you need a 32 mm hose joiner and a second clip, and every extra metre costs a little flow.\u003c\/p\u003e\n\u003ch4\u003eWhat happens when I switch the pump off?\u003c\/h4\u003e\n\u003cp\u003eThe water standing in the hose runs out, either forwards to your discharge point if that end is lower, or back into the pool if it is higher. It is around eight litres, which is nothing against a pool, so it makes no practical difference to the drain. Getting the open end of the hose low simply means it empties the right way.\u003c\/p\u003e\n\u003ch4\u003eCan I leave it running overnight?\u003c\/h4\u003e\n\u003cp\u003eNo. The pump is manual and will not stop when the water runs out, so it needs supervising. On a large pool, split the drain across two sessions rather than leaving it unattended.\u003c\/p\u003e\n\u003ch4\u003eIs it suitable for a saltwater pool?\u003c\/h4\u003e\n\u003cp\u003eYes for the duration of a drain. The 304 stainless construction resists chlorides which is why we chose it. Rinsing through afterwards matters even more with salt than with chlorine, because salt residue crystallises as it dries. For permanent duty in salt water, see our \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/salt-water-pumps\"\u003esalt water pumps\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch4\u003eWill it get the pool completely empty?\u003c\/h4\u003e\n\u003cp\u003eIt will take the level down to the pump's minimum operating depth, which leaves a shallow film on the floor to be squeegeed or wet-vacuumed out. If you need a floor taken back to almost nothing, a \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/puddle-pumps\"\u003epuddle pump\u003c\/a\u003e clears down to a few millimetres.\u003c\/p\u003e\n\u003ch4\u003eCan I use it for a hot tub or spa instead?\u003c\/h4\u003e\n\u003cp\u003eYes, though it is more pump than a hot tub needs. Our \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/products\/hot-tub-emptying-pump-kit?_pos=1\u0026amp;_psq=hot+tub\u0026amp;_psid=cbab93fa9\u0026amp;_ss=e\" title=\"hot tub draining kit\"\u003ehot tub kit\u003c\/a\u003e uses a smaller puddle pump with 6 m of hose and drains a typical tub in about 25 minutes.\u003c\/p\u003e\n\u003ch4\u003eDo you supply a 110 V version?\u003c\/h4\u003e\n\u003cp\u003eYes. A \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/products\/mizar-and-mizar-vox-submersible-pump\" title=\"110 volt mizar swimming pool draining pump\"\u003e110 V Mizar 60\u003c\/a\u003e is available for site and hire use. Call the helpdesk on 0115 987 0358.\u003c\/p\u003e","brand":"FPS Engineered™","offers":[{"title":"Default Title","offer_id":56365065208187,"sku":"MIZAR-60-KIT-POOL-1","price":366.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/0857\/4015\/files\/Heavy_duty_Mizar_swimming_pool_draining_pump_kit.jpg?v=1785871372"},{"product_id":"high-flow-automatic-basement-flood-pump-kit","title":"High-Flow Automatic Basement Flood Pump Kit | Evak Residox 750 - 10m","description":"\u003ch2\u003eHigh-flow automatic basement flood pump kit for deep basements and heavy inflow\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eClears a flooded basement at around 285 litres per minute, and does it on its own.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis FPS Engineered™ kit pairs the automatic EVAK Residox 750 with 10 m of 50mm reinforced suction and delivery hose, a brass non-return valve and a hose clip. Set the pump at the lowest point, run the hose to your discharge point and leave it. The automatic switch does the rest.\u003c\/p\u003e\n\u003cp\u003eThis is the top of our basement range, for the situations where a smaller pump cannot keep up: a deep basement, water coming in faster than it can be cleared, or a long uphill run to the nearest drain. At 330 litres per minute and 16 m of head, the Residox 750 has the capacity to stay ahead of a serious ingress rather than merely cope with it.\u003c\/p\u003e\n\u003cp\u003ePart of our wider \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/basement-waterproofing-pumps\"\u003ebasement waterproofing\u003c\/a\u003e and \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/flood-control\"\u003eflood defence\u003c\/a\u003e ranges.\u003c\/p\u003e\n\u003ch3\u003eAt a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAround 285 litres per minute:\u003c\/strong\u003e Through the 10 m of 50 mm hose supplied, at a typical 2 m lift. Roughly 17,000 litres an hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 metres of head:\u003c\/strong\u003e Enough to lift out of a deep basement and still run a long way to the drain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic float control:\u003c\/strong\u003e Starts and stops with the water, so the space stays protected when nobody is there.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt for abrasive water:\u003c\/strong\u003e Stainless steel case, cast iron housing and a Hytrel vortex impeller that tolerates grit and silt.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface-safe rubber base:\u003c\/strong\u003e Sits directly on a finished floor without marking it, and needs no priming.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × EVAK Residox 750 automatic submersible pump, 230 V, with 10 m H07RN-F cable\u003c\/li\u003e\n\u003cli\u003e1 × 10 m length of 50mm reinforced suction and delivery hose\u003c\/li\u003e\n\u003cli\u003e1 × 50 mm brass non-return valve\u003c\/li\u003e\n\u003cli\u003e1 × 40 to 60mm stainless-steel hose clip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe pump is supplied with its own 2 inch hose tail. \u003c\/p\u003e\n\u003ch3\u003eHow the kit connects\u003c\/h3\u003e\n\u003cp\u003eThe Residox 750 has a 2 inch BSP female top discharge with a hose tail supplied. The brass non-return valve fits between the outlet and the hose, and the 50mm hose pushes fully over the tail and is secured with the clip.\u003c\/p\u003e\n\u003cp\u003eFitting the valve matters more here than on any other kit in the range. With 10 m of 50mm hose you have around 20 litres of water standing in the line, and on a basement job the discharge point is above the pump. Without a valve, all of it drains straight back into the space every time the float cuts out, so the pump starts again and moves the same water twice. On an automatic pump left running unattended, that means needless cycling and wasted motor life.\u003c\/p\u003e\n\u003ch3\u003eAutomatic at floor level, not just automatic\u003c\/h3\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 20px 24px; background: #F0EDE5; border-left: 4px solid #283583; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003e\u003cstrong\u003eMost automatic pumps cannot get near the floor. This one can, because it does not use a float.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eA float switch needs a useful depth of water to lift it. At floor level there is not enough water to do that, so the float drops out early and the pump stops with water still sitting there. \u003c\/p\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eThe automatic Residox uses a \u003cstrong\u003efloor-level sensor\u003c\/strong\u003e instead, a weighted probe called the Crab that rests flat on the ground and detects water by sensing the surface it is sitting on. Nothing has to float, so nothing switches off early. It arrives already wired to the pump, so there is no control panel to mount and no wiring to do.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eThe timing is adjustable with a magnetic key. From the factory the pump starts a few seconds after water is detected and keeps running for around half a minute after the floor is clear, which stops it short-cycling on and off. The sensor works in dirty flood water as well as clear.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eThe result is genuine set-and-forget protection: water arrives, the pump runs, the floor is cleared to near-dry, and it shuts itself off until next time. For the absolute lowest finish, around 1mm, a manual Residox under direct supervision still has the edge, but that means somebody standing there. More on the difference in our guide, \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/blogs\/news\/how-to-pump-water-away-automatically-at-floor-level\"\u003ehow to pump water away automatically at floor level\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eExpected performance\u003c\/h3\u003e\n\u003cp\u003eEstimated flow through the supplied 10 m of 50mm hose with the non-return valve fitted. Uphill lift is measured from the water surface to the point where the hose discharges, so a domestic basement is typically 2 m to 4 m and a deep or split-level one 4 m to 6 m.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eUphill lift\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eEstimated flow\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003ePer hour\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 285 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 17,000 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e4 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 265 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 15,900 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e6 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 240 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 14,400 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow fast will it clear my basement?\u003c\/h3\u003e\n\u003cp\u003eWork out the volume by multiplying floor area in square metres by the water depth in metres, then by 1,000. Times below are at a 4 m lift.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eSpace\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eWater depth\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eEstimated time\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eSmall cellar, 20 m²\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e100 mm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e2,000 litres\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 8 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eBasement, 60 m²\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e100 mm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e6,000 litres\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 23 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eBasement, 60 m²\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e200 mm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e12,000 litres\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 45 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eLarge basement, 100 m²\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e300 mm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e30,000 litres\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 1.9 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #6b7280; line-height: 1.6; margin: 10px 0 0;\"\u003e\u003cem\u003eEstimated using the published Residox 750 curve, Hazen-Williams friction for 50 mm bore and a nominal loss across the non-return valve. Figures assume water is not still coming in. Where there is active ingress, the pump has to clear the standing water and keep pace with the inflow at the same time, so allow longer. The pump is rated for continuous running.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTechnical specification\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eEVAK Residox 750 automatic\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eOperation\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eAutomatic, floor sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003ePump type\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eSubmersible residue and drainage pump, vortex impeller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum flow\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e330 litres per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum head\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e16 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eDischarge\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e2 inch BSP female, top outlet, hose tail supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eFree passage\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMotor power\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e0.75 kW, 1 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eVoltage and current\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e230 V single phase, 11 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMotor speed\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e2,850 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eImpeller\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eHytrel abrasion-resistant vortex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eConstruction\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eStainless steel outer case and handle, cast iron pump housing, alloy motor housing, NBR rubber suction base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eSeal\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eDouble mechanical seal in oil chamber, SIC\/SIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMotor protection\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eAuto-reset thermal protector, cooling jacket for continuous running\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003ePower cable\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e10 metres, H07RN-F heavy duty rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eDuty\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eSuitable for continuous running\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e1 year, manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWhy this pump for a basement\u003c\/h3\u003e\n\u003cp\u003eA basement that floods repeatedly is a harder job than a one-off garage flood, and it asks three things of a pump that a cheap submersible cannot give.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIt has to keep pace with the inflow, not just empty the room.\u003c\/strong\u003e Water entering through a wall or up through a floor does not stop while you pump. 330 litres per minute gives you headroom to clear standing water and stay ahead of what is still arriving.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIt has to lift the water out.\u003c\/strong\u003e A basement discharge point is above the pump by definition, often several metres, and then there is the run to the drain. 16 m of head covers a deep basement and a long horizontal run with capacity left over.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIt has to survive the water it is given.\u003c\/strong\u003e Basement ingress carries grit, silt and building debris. The Hytrel vortex impeller passes 2 mm solids and resists abrasion, the cast iron housing takes the wear, and the stainless case handles the damp. The rubber base means it can sit on a finished floor without marking it, and it needs no priming.\u003c\/p\u003e\n\u003ch3\u003eInstallation and use\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSet the pump at the lowest point of the floor or in the sump, on a firm level base, clear of loose debris and silt.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFit the non-return valve at the pump outlet.\u003c\/li\u003e\n\u003cli\u003eRun the hose to a foul drain or an approved discharge point, and avoid tight bends that will restrict the flow.\u003c\/li\u003e\n\u003cli\u003eKeep the plug and connections dry and above any possible water level, and never lift or suspend the pump by its cable.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 18px 22px; background: #FBF9F3; border: 1px solid #E5DED8; border-left: 4px solid #E8542B; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003e\u003cstrong style=\"color: #c8431d;\"\u003eA pump is not a waterproofing system.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eIf a basement floods repeatedly, the water is getting in for a reason, and a pump manages the symptom rather than the cause. For habitable basements, and anywhere a failure would damage property, a pumped system should be designed rather than assembled: that usually means a sealed sump, a correctly sized chamber, a second pump for redundancy, a battery backup and a high-level alarm. Our \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/pages\/engineering-review\"\u003eengineering review service\u003c\/a\u003e covers that. This kit is the right answer for a cellar, store or plant space where a single automatic pump is proportionate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWater quality limits\u003c\/h3\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 18px 22px; background: #FBF9F3; border: 1px solid #E5DED8; border-left: 4px solid #E8542B; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eClean and dirty water, with solids to 2 mm.\u003c\/strong\u003e The Residox is built to tolerate grit and abrasive material better than most, but it is not a sewage or solids-handling pump. Not for foul water, sewage or salt water. Where the water contains settled silt and fines, the \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/products\/evak-trenchman-site-pumps\"\u003eEVAK Trenchman\u003c\/a\u003e with its agitator is the better tool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4\u003eHow low will it pump automatically?\u003c\/h4\u003e\n\u003cp\u003eFar lower than a float-operated pump. The floor-level sensor rests on the ground rather than floating, so nothing switches off early and the floor is cleared to near-dry. For the absolute lowest finish, around 1 mm, a manual Residox under direct supervision still has the edge.\u003c\/p\u003e\n\u003ch4\u003eDo I need a control panel or any wiring?\u003c\/h4\u003e\n\u003cp\u003eNo. The floor-level sensor is supplied already wired to the pump, so there is nothing to mount and nothing to wire in. Plug it in, lay the sensor on the floor and it is working.\u003c\/p\u003e\n\u003ch4\u003eIs a 110 V version available?\u003c\/h4\u003e\n\u003cp\u003eNot on the automatic. The Residox 400 and 750 Automatic are 230V only, because that is what suits the domestic and commercial mains installations they are designed for. If you need 110 V for site use through a transformer, choose a \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/products\/evak-residox-750-powerful-puddle-sucker-pumps-high-flow-flood-pump?_pos=2\u0026amp;_psq=residox\u0026amp;_psid=bbb8bc922\u0026amp;_ss=e\u0026amp;variant=56226740863355\" title=\"Manual Evak Residox Water Pump\"\u003emanual Residox\u003c\/a\u003e instead.\u003c\/p\u003e\n\u003ch4\u003eCan I leave it in the basement permanently?\u003c\/h4\u003e\n\u003cp\u003eYes, that is what the automatic float switch is for, and the pump is rated for continuous running. Check the float, intake and non-return valve periodically, because a pump nobody inspects is not reliable protection. For a habitable basement, a designed system with a backup pump and an alarm is the right answer rather than a single pump.\u003c\/p\u003e\n\u003ch4\u003eHow is this different from the Automatic Home Basement kit?\u003c\/h4\u003e\n\u003cp\u003eCapacity. The home kit uses an SPP2 at 70 litres per minute and 6 m of head, which suits a domestic cellar with occasional modest ingress. This kit moves more than four times the water and lifts it nearly three times as high, so it is for deep basements, heavy inflow, or a long uphill run to the drain.\u003c\/p\u003e\n\u003ch4\u003eWhy does the kit include a non-return valve?\u003c\/h4\u003e\n\u003cp\u003eBecause 10 m of 50mm hose holds around 20 litres, and on a basement job the discharge point is above the pump. Without a valve, that water runs back into the basement every time the float cuts out, so the pump restarts and moves the same water again. The valve stops the cycling.\u003c\/p\u003e\n\u003ch4\u003eDo I need a bigger hose than the one supplied?\u003c\/h4\u003e\n\u003cp\u003eNo. The 50 mm hose matches the pump's 2 inch outlet, which is what allows it to deliver around 285 litres per minute. Narrowing the discharge is the commonest way a capable pump is throttled: dropping to 32 mm bore would cost you nearly 30 percent of the flow.\u003c\/p\u003e\n\u003ch4\u003eCan it handle silty or muddy water?\u003c\/h4\u003e\n\u003cp\u003eBetter than most. The Hytrel vortex impeller is abrasion resistant and passes solids to 2 mm, and the cast iron housing takes the wear. \u003c\/p\u003e","brand":"FPS Engineered™","offers":[{"title":"Default Title","offer_id":56372158169467,"sku":"RESIDOX-750-KIT-BASEMENT-1","price":656.57,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/0857\/4015\/files\/Automatic_Evak_Residox_with_Crab_Floor_sensor_3.jpg?v=1786367345"},{"product_id":"contractor-dewatering-pump-kit-tsurumi-lb480","title":"Contractor Dewatering Pump Kit | Tsurumi LB480","description":"\u003ch2\u003eContractor dewatering pump kit for excavations, site water and flood response\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThe pump contractors ask for by name, supplied with the hose to actually use it.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis FPS Engineered™ kit pairs the Tsurumi LB480 with 20m of 50mm layflat hose and a stainless-steel clip. The pump takes its own hose tail, so it connects straight out of the box. Choose 110 V for site power through a transformer, or 230 V for building mains.\u003c\/p\u003e\n\u003cp\u003eWe have been UK distributors of Tsurumi since 2012, and the LB480 is the model that comes back for more. It is not the cheapest 2 inch dewatering pump we could put in a kit. It is the one that is still working after a winter of being loaded wet into a van, run by whoever was on site that day, and asked to clear footings again the next morning.\u003c\/p\u003e\n\u003cp\u003ePart of our wider \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/tsurumi-pumps\"\u003eTsurumi\u003c\/a\u003e, \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/site-drainage-pumps\"\u003esite drainage\u003c\/a\u003e and \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/collections\/110v-water-pumps\"\u003e110 V pump\u003c\/a\u003e ranges.\u003c\/p\u003e\n\u003ch3\u003eAt a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAround 190 litres per minute:\u003c\/strong\u003e Through the 20 m of layflat supplied, at a typical 2m lift. Roughly 11,400 litres an hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6mm free passage:\u003c\/strong\u003e Passes the grit, sand and light debris that comes with site water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual discharge option:\u003c\/strong\u003e 50mm - set horizontally or vertically to prevent hose kinks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-wicking cable:\u003c\/strong\u003e A Tsurumi standard. Stops water tracking along the conductors into the motor if the cable end ever gets wet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20m of layflat that stores:\u003c\/strong\u003e Rolls flat into a fraction of the space reinforced hose takes, which matters in a van.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Tsurumi LB480 submersible dewatering pump, with hose tail fitted\u003c\/li\u003e\n\u003cli\u003e1 × 20m length of 50 mm layflat hose\u003c\/li\u003e\n\u003cli\u003e1 × 40 to 60mm stainless-steel hose clip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eChoose 230 V for buildings and general-purpose mains, or 110 V for construction sites running through a transformer. Same pump, same hose, same fittings.\u003c\/p\u003e\n\u003ch3\u003eHow the kit connects\u003c\/h3\u003e\n\u003cp\u003eThe LB480 has a 2 inch top discharge with its own hose tail, so there is nothing to source and nothing to adapt. Slide the layflat over the tail and tighten the clip. That is the whole assembly.\u003c\/p\u003e\n\u003cp\u003eThe discharge can be set to run either vertically or horizontally. In a narrow sump or a deep footing, vertical keeps the hose rising straight out of the chamber with nothing pressing against the walls. In a shallow puddle, a crawl space or under a floor where there is no headroom, horizontal lets the hose run away flat instead of standing up and folding over on itself. Being able to switch it means one pump suits both, rather than you working around whichever orientation it happened to come in.\u003c\/p\u003e\n\u003ch3\u003eExpected performance\u003c\/h3\u003e\n\u003cp\u003eEstimated flow through the supplied 20m of 50mm layflat with the hose discharging freely. Uphill lift is measured from the water surface to the point where the hose discharges.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eUphill lift\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eTypical situation\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eEstimated flow\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003ePer hour\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eShallow footings, ground level discharge\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 190 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 11,400 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e4 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eExcavation up to a kerb or gully\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 167 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 10,000 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e6 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eDeep excavation or basement slab\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 141 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 8,500 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003e8 m\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApproaching the pump's limit\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 109 L\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eApprox. 6,500 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #6b7280; line-height: 1.6; margin: 10px 0 0;\"\u003e\u003cem\u003eEstimated using the published LB480 curve and Hazen-Williams friction for 50 mm bore. At 167 litres per minute a 3 m × 2 m excavation with a metre of water in it, around 6,000 litres, clears in roughly 36 minutes. Friction across the full 20 m run is under 1.2 m of head, so almost all the pump's capability goes into lift rather than being lost in the hose. Work out a specific run with our \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/pages\/hose-pipe-friction-loss-calculator\"\u003epump performance calculator\u003c\/a\u003e.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTechnical specification\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; border: 1px solid #E5DED8; border-radius: 10px; margin: 22px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px; background: #ffffff;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"background: #283583; color: #fbf9f3; text-align: left; padding: 11px 14px; font-weight: 600;\"\u003eTsurumi LB480\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003ePump type\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eSubmersible dewatering pump, clean and dirty water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum flow\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e225 litres per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMaximum head\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e11 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eFree passage\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eDischarge\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e50 mm, 2 inch, horizontal or vertical with hose tail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMotor power\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e0.48 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003e110 V or 230 V single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FBF9F3;\"\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eCable\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eAnti-wicking cable entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118; font-weight: 600;\"\u003eMotor protection\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 14px; border-top: 1px solid #E5DED8; color: #0c1118;\"\u003eBuilt-in motor protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWhy contractors keep buying Tsurumi\u003c\/h3\u003e\n\u003cp\u003eTsurumi have been making pumps in Japan since 1924, and the dewatering range is what the name is built on. Two details explain why the LB480 turns up on so many sites.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe anti-wicking cable.\u003c\/strong\u003e Water finds its way along the inside of a cable, between the conductors, and into the motor. It is one of the commonest ways a site pump dies, and it usually happens because someone left a cable end lying in water. Tsurumi seal against it as standard across the range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe motor protector.\u003c\/strong\u003e Site pumps get run dry, run against a kinked hose and run in water that is thicker than it should be. The built-in protector cuts the motor before damage rather than after.\u003c\/p\u003e\n\u003ch3\u003e110 V or 230 V?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e110 V\u003c\/strong\u003e for construction sites, where power comes through a transformer. Site rules generally require it, and a 230 V pump is no use where there are only 110 V outlets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e230 V\u003c\/strong\u003e for buildings, plant rooms, commercial premises and domestic properties on normal mains.\u003c\/p\u003e\n\u003cp\u003eIf you work across both, most fleets standardise on 110 V and carry a transformer. Both versions are the same pump with the same performance.\u003c\/p\u003e\n\u003ch3\u003eWhat can I use it for?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDewatering excavations, footings and trenches\u003c\/li\u003e\n\u003cli\u003eClearing surface water from site compounds, hard standings and access roads\u003c\/li\u003e\n\u003cli\u003eFlood response in commercial units, basements and plant rooms\u003c\/li\u003e\n\u003cli\u003eEmptying tanks, chambers, lift pits and manholes\u003c\/li\u003e\n\u003cli\u003eGroundworks, civils and utilities work where water has to be moved daily\u003c\/li\u003e\n\u003cli\u003eHire fleet stock, where the same kit needs to cover several kinds of job\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWater quality limits\u003c\/h3\u003e\n\u003cdiv style=\"margin: 26px 0; padding: 18px 22px; background: #FBF9F3; border: 1px solid #E5DED8; border-left: 4px solid #E8542B; border-radius: 8px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eClean and dirty water, solids to 6 mm.\u003c\/strong\u003e The LB480 handles the grit and sand that comes with site water, but it is not a solids-handling or sewage pump. Where the water carries settled silt and fines that need stirring back into suspension, the \u003ca href=\"https:\/\/floodandwaterpumps.co.uk\/products\/evak-trenchman-site-pumps\"\u003eEVAK Trenchman\u003c\/a\u003e has a built-in agitator and 15 mm free passage and is the right pump for it. Not for foul water, sewage or salt water.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4\u003eWhy is there no choice of hose length?\u003c\/h4\u003e\n\u003cp\u003eBecause at 50 mm bore it would not change anything. Going from 10m to 20m of 50mm layflat costs around 3 percent of the flow, which is smaller than the margin of error on the estimate. Rather than ask you to pick between two options that perform the same, we supply the longer one, since running short stops a job and running long does not. Hose can be cut to length to suit your needs. \u003c\/p\u003e\n\u003ch4\u003eDo I need to buy a hose tail?\u003c\/h4\u003e\n\u003cp\u003eNo. The LB480 comes with its own 2 inch hose tail fitted, so the layflat goes straight on with the supplied clip. Nothing else to source.\u003c\/p\u003e\n\u003ch4\u003eWhich voltage should I choose?\u003c\/h4\u003e\n\u003cp\u003e110 V for construction sites running through a transformer, which is what site rules generally require. 230 V for buildings, plant rooms and domestic mains. The pump performs identically either way.\u003c\/p\u003e\n\u003ch4\u003eHow is it different from the Trade \u0026amp; Hire Flood kit?\u003c\/h4\u003e\n\u003cp\u003eDifferent jobs. The SPK530 kit clears indoor floods, with reinforced hose for steps and doorways and a pump that takes water down to 1 mm. This kit is for excavations and site water: bigger bore, more flow through the hose, and a pump built for daily site abuse. If you need both, most fleets carry both.\u003c\/p\u003e\n\u003ch4\u003eCan I add more hose?\u003c\/h4\u003e\n\u003cp\u003eYes, and at 50 mm it costs very little. Another 20 m would take roughly another 3 percent off. You need a 50 mm joiner and a second clip. Get the water somewhere safe as directly as you can, and avoid tight bends, which cost far more than length does.\u003c\/p\u003e\n\u003ch4\u003eWill it pump silty or muddy water?\u003c\/h4\u003e\n\u003cp\u003eIt passes solids to 6 mm and handles the grit and sand that comes with most site water. Where silt has settled and needs stirring back into suspension, a pump with an agitator is the right tool, because a standard dewatering pump will simply pump clear water off the top and leave the silt behind.\u003c\/p\u003e\n\u003ch4\u003eWhy Tsurumi rather than a cheaper 2 inch pump?\u003c\/h4\u003e\n\u003cp\u003eLongevity and serviceability. The anti-wicking cable entry protects against one of the commonest causes of site pump failure, the motor protector cuts in before damage rather than after, and a Tsurumi is worth repairing rather than replacing. Across a fleet that changes the cost of ownership considerably.\u003c\/p\u003e","brand":"FPS Engineered™","offers":[{"title":"110V","offer_id":56373467021691,"sku":"LB480-KIT-CONTRACTOR-110","price":356.94,"currency_code":"GBP","in_stock":true},{"title":"230V","offer_id":56373467054459,"sku":"LB480-KIT-CONTRACTOR-230","price":361.94,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/0857\/4015\/files\/Tsurumi_LB480_Contractor_Dewatering_Pump_Kit.jpg?v=1786452335"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/0857\/4015\/collections\/Automatic_Evak_Residox_with_Crab_Floor_sensor_4.jpg?v=1786454725","url":"https:\/\/floodandwaterpumps.co.uk\/collections\/pump-kits.oembed","provider":"Flood \u0026 Water Pumps","version":"1.0","type":"link"}