Evak Hippo 100 Sewage Pump (11m Head Lift) DN50-100
- Impressive Solids Handling (50mm free passage)
- Perfect for sewage, drainage and dirty water
- Heavy Duty
- Impressive Flow Rate
Sewage pumps move foul water and wastewater from below-ground chambers, basements and bathrooms up to the main sewer or treatment plant where gravity drainage isn't possible. Our range covers vortex, cutter and grinder pumps for domestic...
Sewage pumps move foul water and wastewater from below-ground chambers, basements and bathrooms up to the main sewer or treatment plant where gravity drainage isn't possible. Our range covers vortex, cutter and grinder pumps for domestic, commercial and industrial foul water applications, with next-day UK delivery.
Sewage pumps (also called foul water pumps or wastewater pumps) are used wherever gravity drainage to the main sewer isn't possible.
The most common scenarios include basement bathrooms, properties built below street level, garden offices and annexes, cellar conversions, commercial kitchens, and sites where the fall on the drainage pipe is insufficient for gravity flow.
Unlike a standard submersible, a sewage pump is specifically engineered to handle liquids containing solids and organic matter. The technical term for this in pumping is "dirty water."
For a full technical walkthrough including gravity drainage gradients under Building Regs and BS EN 12056, Section 106 agreements, and system design, read our Ultimate Guide to Sewage Pumps.
The deeper read: what's in this range, how to pick, and when to talk to us before you buy.
Sewage pumps are used across a wide range of applications:
The preferred option on any build is always gravity drainage, which directs sewage to flow down the natural slope of the land. When that isn't possible, a sewage pump is required.
Because sewage pumps have to handle liquids containing solids, they are built differently from standard water pumps. There are three main types:
1. Vortex Impeller Pumps
Vortex pumps are designed to allow unimpeded passage of solids. The impeller creates a whirlpool effect that moves solids through the pump without them ever touching the blades. Pumps like the EVAK Hippo 50, Hippo 75, Hippo 100 and Hippo 200 have a free passage of up to 50mm. In the product video you'll see them pumping table tennis balls through without clogging, or damaging the balls. Vortex pumps are the default choice for most domestic and light commercial sewage applications.
2. Cutter Pumps
Cutter pumps, like the APP DSPK Cutter Sewage Pump, are fitted with a cutting blade that chops solids into smaller pieces before pumping. They are ideal for fibrous materials, wet wipes and tough waste that would otherwise clog a standard pump. Cutter pumps are a strong choice where the downstream pipework is narrow or the pump is serving a public-facing site (pubs, offices, holiday lets) where non-flushables frequently enter the system.
3. Grinder Pumps
Grinder pumps, like the Speroni Cutty, use a grinding mechanism to reduce solids to a slurry, allowing the sewage to be pumped through small-bore pipework over long distances. They are commonly specified for sewage pumping stations where the discharge main is smaller than standard, or where long pipe runs make a grinder the most efficient option.
A sewage pump sits on a stand inside a chamber and has large inlet openings to allow solids to pass through. This is the critical difference between a sewage pump and a puddle pump or drainage pump. A sewage pump cannot pump down to low water levels, because the openings required for solids handling would simply pass air once the level dropped.
Most sewage pumps use pendant float switches rather than tube floats or sensors, because pendant floats are far less likely to snag or clog in foul water.
Sewage pumps are designed to run in bursts (on-off cycles) rather than continuously. When the chamber fills, the float switch triggers the pump, and it runs until the level drops. This is why correct sizing matters: an oversized pump will short-cycle, which shortens the life of the motor and float.
For installations that need a complete, ready-to-install solution (basement bathrooms, ground floor extensions, or any site where foul water needs collecting and pumping away), we supply Packaged Pump Stations, with options built around the Hippo and FEKA pump families.
Each packaged pump station is supplied with the chamber, pump, internal pipework, non-return valve and float switch, ready to install. We continue to expand this range.
For deeper reading on head, flow and system design, see our Ultimate Guide to Sewage Pumps or use the Water Pump Performance Calculator to work out pipe friction losses.
The single most common mistake when buying a sewage pump is picking one on maximum head or maximum flow alone. Both figures are the absolute top of the pump's range, and a pump working at its maximum head produces almost no flow, while a pump at maximum flow has almost no pressure left to push the water anywhere.
A pump curve plots head against flow and shows you what the pump will actually deliver at every point in between. Once you know the head you need to overcome (vertical lift plus friction losses along the pipe run), the curve tells you the flow rate you'll get at that head, which is the number that actually matters.
This short video walks through how to read a pump curve and select the right pump for your application:
All sewage pumps can become "ragged" over time, particularly where wet wipes, sanitary products or other non-flushables have entered the system. De-ragging involves isolating the pump, lifting it from the chamber and clearing the impeller and inlet.
To minimise de-ragging, only flush toilet paper and organic waste down any toilet connected to a sewage pump. Wet wipes, even those labelled "flushable," are the single biggest cause of sewage pump callouts. If the site is public-facing or occupied by tenants, specifying a cutter pump or grinder pump from the outset will dramatically reduce maintenance calls.
We've spent years sourcing and testing sewage pumps across our hire, supply and consultancy work, and we only stock pumps we'd specify on our own drainage projects. Every pump in the range is backed by a manufacturer warranty (many with 2 or 3 years), supported by our UK helpdesk on 0115 987 0358, and held in stock at our Nottingham warehouse for next-day delivery across the UK.
If you're unsure which sewage pump is right for your application, call the helpdesk. We'd rather not sell you the wrong pump.
We're the pump supply arm of Flood Protection Solutions Ltd, trading since 2012. Our sister company, also part of the FPS Group®, is FPS Environmental Ltd, who offer foul drainage design and consultancy for new builds, conversions, developments and pump station design, from initial concept and planning through to detailed system design.