PUMP CATEGORY

Flood Pumps & Flood Control Equipment

Flood control equipment for managing water before, during and after a flood event. This collection brings together pumps used to remove flood water and physical barriers used to keep it out.

You will find puddle pumps, submersible pumps, engine-driven pumps, packaged pump stations, flood barriers, airbrick covers and ready-to-deploy flood kits. All selected based on real-world engineering experience, with UK stock available.

Read our guide: Garage Flooding: Choosing the Right Pump

Products in range 55
From £21£17.50 (Exc VAT)
Use case Flood mitigation
Range Engineer-selected
55 products
Tsurumi

Tsurumi OM5 Submersible Sump Pump

  • Manual or auto · tube float on 222mm / off 61mm
  • 195 L/min · 7.5m head
  • 32mm outlet · 10mm free passage
  • 110V or 230V · 3-year warranty
  • Slim 140mm body for narrow sumps
£343.00 £285.83 (Exc VAT)
In stock
View
Tsurumi

Tsurumi TE Petrol Site Pump | Honda Engine Water Pump

  • Honda petrol (GX25–GX160) · self-priming
  • 130–1,000 L/min · 32–40m head (by model)
  • 1–3" inlet/outlet · 5–6mm free passage
  • 8m max suction lift · 3-year warranty
  • Cleaner-water site pump, 4 sizes
£385.00 £320.83 (Exc VAT)
In stock
View
Drymax

DryMax Diesel Powered Water Trash Pump

  • Yanmar L48E diesel · auto-priming diaphragm
  • 190–330 L/min · 17m head (by model)
  • 2" or 3" inlet/outlet · 40mm free passage
  • 8m max suction lift · 2-year warranty
  • Runs dry indefinitely, up to 6 hours on a tank
£6,825.00 £5,687.50 (Exc VAT)
In stock
View
Tsurumi

Tsurumi TD Petrol Diaphragm Trash Pump

  • Honda GX120 petrol · auto-priming diaphragm
  • 120 L/min · 17m head
  • 2" inlet/outlet · 30mm free passage
  • 6m suction lift · 3-year warranty
  • Handles sludge, sand and silt, can run dry briefly
£2,185.00 £1,820.83 (Exc VAT)
In stock
View
EVAK

Evak Hippo 75 Sewage Pump (10m Head Lift) DN50-75

  • Auto float (110V/230V) or manual (400V)
  • 390 L/min · 10m head
  • 50mm outlet · 50mm free passage
  • 110V, 230V or 400V · 1-year warranty
  • 3m more lift than the Hippo 50, same body size
£369.00 £307.50 (Exc VAT)
Some options out of stock
View
Flood control: removing water and helping stop it getting in.

Flood control: removing water and helping stop it getting in.

Flood control is about managing water when it arrives, not just preventing it. Effective property-level flood response usually combines two elements: removing water that has already entered, and preventing further ingress. This collection covers both.

The right approach depends on the source of flooding, the depth and volume of water, whether mains power is available, and how quickly water needs to be moved.

For active flood situations, pumps are the priority. For properties at known risk, barriers and protection measures are typically deployed in advance.

Why flood defence schemes need pumps.

Pumps are the part of a flood defence scheme people forget, yet no scheme is really complete without one. Barriers, flood doors, walls and embankments reduce how much water reaches a property or asset, but no defence is ever perfect. Water still arrives through seepage, through groundwater rising beneath a wall, or as surface water that becomes trapped on the dry side with nowhere to drain. A pump removes that water before it causes damage, which is why pumps are designed into flood schemes at every scale. We explain the principle in full in our guide to the importance of pumps in a flood defence scheme.

Property flood resilience pumping.

At the smaller, property scale, this is the heart of Property Flood Resilience (PFR). A resilient home combines barriers, flood doors and airbricks to keep most water out, with an automatic pump as the last line of defence to clear whatever gets past, quietly and without anyone present. You can see how this works in our guide to sump pumps and property flood resilience and our pick of the best automatic pump for a flooded basement, and in real installations: an EVAK Residox pump behind a flood barrier, an EGO 500 GI behind a flood wall, and an APP RS32EA protecting a flooded doorway. For choosing the pump itself, see our top puddle pumps for flood and dewatering.

Larger scale engineering flood control.

At the larger, civil engineering scale, pumps do the same job on a bigger footing. They dewater excavations and cofferdams while defences are being built, provide over-pumping and temporary works during construction, and form permanent pumping stations that lift water over or through a defence where it cannot drain away by gravity. Reliability is everything at this scale, which is why the same pumps we supply to homeowners are trusted by the Environment Agency, water companies and councils, and why our flood work has featured on BBC Rip Off Britain. And as flash flooding becomes more frequent, having the right pumping in place matters more than ever, as we cover in our guide to preparing for flash flooding.

Pumps for flood water removal.

Pumps for flood water removal.

Buying guide

More about flood pumps.

Our Flood Control Pumps range brings together a selection of pump types commonly used for flood response, emergency water removal and drainage. This includes puddle pumps, submersible pumps, engine driven pumps and more, with links below to browse each dedicated pump category.

Puddle Pumps

Designed to remove water down to very low residual levels, typically 1 to 5mm. Puddle pumps are used for final clean-up after flooding or where a standard submersible pump leaves water behind. Suitable for clean to lightly contaminated water. Available in automatic or manual.

Evak Residox Puddle Pump with Automatic Sensor in Flooded Home
Evak Residox Puddle Pump with Automatic Sensor in Flooded Home

Submersible Flood Pumps

General-purpose submersible pumps for moving large volumes of water quickly. Commonly used in flooded basements, garages, cellars, outbuildings and external areas. Most models handle clean to lightly soiled water, with sewage-rated options available where contamination is present.

Engine-Driven Pumps

Used where mains power is unavailable, has failed, or where higher flow rates are required. Engine Driven Pumps are suitable for severe flooding, agricultural land, remote sites and large-scale dewatering. Available in petrol and diesel depending on duty requirements.

Packaged Pump Stations

Permanent, automatic systems installed below ground to manage water as part of a long-term flood resilience strategy. Packaged Pump Stations are typically used where water needs to be lifted and discharged automatically, such as basements, low-lying properties, or developments below sewer level.

Packaged Pump Station installed behind a Flood Wall into a patio to provide "passive" pumping. The pump will activate during a flood using the float switch.
Packaged Pump Station installed behind a Flood Wall into a patio to provide "passive" pumping. The pump will activate during a flood using the float switch.

Property-Level Flood Protection

Pumps deal with water once it has entered. Physical flood protection products are used to reduce or prevent water entering in the first place, typically deployed when a flood warning is issued.

  • Door and opening barriers – Installed across doorways and openings to block surface water entry
  • Water-activated – Sandbag alternatives that expand on contact with water to seal thresholds and gaps
  • Airbrick covers – Prevent water ingress through airbricks, a common source of internal flooding
  • Rapid-response flood kits – Pre-assembled kits for fast deployment during flood warnings

These systems are most effective when used together. A typical setup combines a flood barrier, airbrick covers and a flood kit, supported by a pump for any residual water.

Property-Level Flood Protection

Important Information: Bespoke Barriers and Flood Risk Surveys

Flood & Water Pumps is part of Flood Protection Solutions Ltd, within the wider FPS Group®.

If you require a bespoke or permanent flood barrier system (such as aluminium demountable barriers engineered for a specific opening), these are not stocked products and are designed on a project basis. You can obtain a quote from Flood Protection Solutions here: Flood Barrier Enquiry.

If you require a flood risk survey, site assessment or engineered flood resilience design, this is delivered through FPS Environmental Ltd on a formal instruction basis.

This collection is product supply only. Where a project requires investigation, design or consultancy input, these services are provided separately by the consultancy team.

Common questions

Frequently asked questions.

What is the best pump for flooding?

It depends on how the water arrives and how low you need to go. A puddle pump such as the Tsurumi LSC1.4S or Stream SPK530 clears floors down to about 1 mm, a submersible drainage or site pump moves more water where it is deeper, and a petrol pump such as the Honda WB20 works where there is no power.

Should I buy a manual or automatic flood pump?

An automatic pump starts and stops itself on a float or sensor, so it suits cellars, basements and doorways that flood while you are away. A manual pump is cheaper and fine when you will be there to switch it on and off, but it should not be left running dry.

Do I need a pump if I have flood barriers?

Usually, yes. Barriers help prevent ingress but some still seeps through the ground, walls, or rain may fall inside the protected area. A pump behind the barrier removes that water before it builds up.

What if the power goes off during a flood?

Electric pumps stop in a power cut, so keep a petrol pump such as the Honda WX10, WB20 or WB30 as a backup. Petrol pumps must be run outdoors because of exhaust fumes.

Do flood pumps come with a hose?

Pumps are sold without hose unless they are part of a kit. Our flood pump kits include a matched hose and fittings, or you can choose layflat or suction and delivery hose separately.