PUMP CATEGORY

Flood Control Equipment, Pumps, Barriers & Property Protection

Flood control equipment for managing water before, during and after a flood event. This collection brings together pumps used to remove flood water and physical barriers used to keep it out. You will find puddle pumps, submersible pumps,...

Products in range 43
From £15.48£12.90 (Exc VAT)
Use case Flood mitigation
Advice Engineer-led
43 products
Tsurumi Pumps 5.0

Tsurumi OM5 Submersible Sump Pump

  • Manual and auto models available
  • Narrow float switch on auto model
  • Perfect for narrow sumps and chambers
£335.00 £279.17 (Exc VAT)
In stock
View
Tsurumi Pumps

Tsurumi TE Petrol Site Pump

  • Self-priming petrol centrifugal pump
  • Powered by Honda 4 stroke petrol engine
  • Abrasion resistant
£324.38 £270.32 (Exc VAT)
In stock
View
Tsurumi Pumps

DryMax Diesel Powered Water Trash Pump

  • Automatic priming diaphragm pump
  • Perfect for pumping site sludge, mud, sewage, sand and solids up to 40mm
  • Can run dry indefinitely
£4,894.12 £4,078.43 (Exc VAT)
In stock
View
Tsurumi Pumps

Tsurumi TD Petrol Diaphragm Trash Pump

  • Suitable for trash, sand, silts and solids up to 30mm
  • OHV Honda petrol powered automatic priming diaphragm pump
  • Can run dry for short periods
£1,567.02 £1,305.85 (Exc VAT)
In stock
View
EVAK

EVAK Residox 400 Automatic Puddle Pump

  • Automatic puddle pump with integrated floor-level sensor
  • Detects water at 3 mm (±1 mm) above the floor
  • Adjustable delays prevent rapid on/off cycling, protecting the motor
  • Plugs straight into 230V mains, no control panel required
  • Full Residox 400 build, 250 l/min, 11 m head
£499.17 £415.98 (Exc VAT)
In stock
View
EVAK

EVAK Residox 750 Automatic Puddle Pump

  • High-flow automatic puddle pump with integrated automatic sensor
  • Detects water at 3 mm (±1 mm) above the floor
  • Adjustable delays prevent rapid on/off cycling, protecting the motor
  • Plugs straight into 230V mains, no control panel required
  • Larger areas, deeper sumps, longer runs, uphill discharge
£582.50 £485.42 (Exc VAT)
In stock
View
EVAK

EVAK Residox 750 Manual Puddle Pump

  • Highest Flow Rate of Puddle Pump Range
  • 330 l/min flow, 16 m head, built for larger floods and uphill discharge
  • Stainless steel build, cast iron housing, Hytrel impeller
  • 2 mm free passage and surface-safe base
  • 110V or 230V, no priming required
£482.50 £402.08 (Exc VAT)
In stock
View
Flood Protection Solutions

EGO 500 GI LS Submersible Puddle Pump | Dual Automatic and Manual | Low Level Pumping

  • Pumps down to just 1mm in manual mode for clean-water low-level-suction applications
  • Dual manual or automatic operation via mechanical float switch
  • Auto mode starts at 130mm, stops at 70mm
  • Flat-base low-suction body restricts inlet to 1mm (clean water only)
  • More affordable than the SE LS where electronic sensors aren't needed
£185.00 £154.17 (Exc VAT)
In stock
View
Tsurumi Pumps

Tsurumi LSC 1.4S (Automatic) Puddle Pumps

  • Pumps as low as 1mm with sensor probes
  • Heavy duty automatic puddle pump
  • Used widely by hire, utilities and water companies
  • Adjustable vertical or horizontal outlet
£729.17 £607.64 (Exc VAT)
In stock
View
Flood Control: Removing Water and Helping Stop It Getting In

Flood Control: Removing Water and Helping Stop It Getting In

Flood control is about managing water when it arrives, not just preventing it. Effective property-level flood response usually combines two elements: removing water that has already entered, and preventing further ingress. This collection covers both.

The right approach depends on the source of flooding, the depth and volume of water, whether mains power is available, and how quickly water needs to be moved.

For active flood situations, pumps are the priority. For properties at known risk, barriers and protection measures are typically deployed in advance.

Pumps for Flood Water Removal

Pumps for Flood Water Removal

In an active flood, pumps are often a first line of response. The correct choice depends on water depth, required flow rate, and available power on site.

Puddle Pumps

Designed to remove water down to very low residual levels, typically 1–5mm. These are used for final clean-up after flooding or where a standard submersible pump leaves water behind. Suitable for clean to lightly contaminated water.

Submersible Flood Pumps


General-purpose pumps for moving large volumes of water quickly. Commonly used in flooded basements, garages, cellars, outbuildings and external areas. Most models handle clean to lightly soiled water, with sewage-rated options available where contamination is present.

Engine-Driven Pumps

Used where mains power is unavailable, has failed, or where higher flow rates are required. Suitable for severe flooding, agricultural land, remote sites and large-scale dewatering. Available in petrol and diesel depending on duty requirements.

Packaged Pump Stations

Permanent, automatic systems installed below ground to manage water as part of a long-term flood resilience strategy. Typically used where water needs to be lifted and discharged automatically, such as basements, low-lying properties, or developments below sewer level.

If you are unsure which pump is suitable, use the Water Pump Performance Calculator to estimate flow rate and head requirements.

Buying guide

More about this category.

The deeper read: what's in this range, how to pick, and when to talk to us before you buy.

Puddle Pumps

Designed to remove water down to very low residual levels, typically 1 to 5mm. These are used for final clean-up after flooding or where a standard submersible pump leaves water behind. Suitable for clean to lightly contaminated water.

Submersible Flood Pumps

General-purpose pumps for moving large volumes of water quickly. Commonly used in flooded basements, garages, cellars, outbuildings and external areas. Most models handle clean to lightly soiled water, with sewage-rated options available where contamination is present.

Engine-Driven Pumps

Used where mains power is unavailable, has failed, or where higher flow rates are required. Suitable for severe flooding, agricultural land, remote sites and large-scale dewatering. Available in petrol and diesel depending on duty requirements.

Packaged Pump Stations

Permanent, automatic systems installed below ground to manage water as part of a long-term flood resilience strategy. Typically used where water needs to be lifted and discharged automatically, such as basements, low-lying properties, or developments below sewer level.

Property-Level Flood Protection

Pumps deal with water once it has entered. Physical flood protection products are used to reduce or prevent water entering in the first place, typically deployed when a flood warning is issued.

  • Door and opening barriers – Installed across doorways and openings to block surface water entry
  • Water-activated – Sandbag alternatives that expand on contact with water to seal thresholds and gaps
  • Airbrick covers – Prevent water ingress through airbricks, a common source of internal flooding
  • Rapid-response flood kits – Pre-assembled kits for fast deployment during flood warnings

These systems are most effective when used together. A typical setup combines a door barrier, airbrick covers and a flood kit, supported by a pump for any residual water.

Important Information: Bespoke Barriers and Flood Risk Surveys

Flood & Water Pumps is part of Flood Protection Solutions Ltd, within the wider FPS Group®.

If you require a bespoke or permanent flood barrier system (such as aluminium demountable barriers engineered for a specific opening), these are not stocked products and are designed on a project basis. You can obtain a quote from Flood Protection Solutions here: Flood Barrier Enquiry.

If you require a flood risk survey, site assessment or engineered flood resilience design, this is delivered through FPS Environmental Ltd on a formal instruction basis.

This collection is product supply only. Where a project requires investigation, design or consultancy input, these services are provided separately by the consultancy team.